Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 215

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

In Vivo Three-Dimensional High-Resolution Imaging of Rodent Retina with Spectral-Domain Optical Coherence Tomography

Ruggeri, Marco, Wehbe, Hassan, Jiao, Shuliang, Gregori, Giovanni, Jockovich, Maria E., Hackam, Abigail, Duan, Yuanli, Puliafito, Carmen A. · 2007 · Investigative Opthalmology & Visual Science

Abstract

PURPOSE: To demonstrate the application of high-resolution spectral-domain optical coherence tomography (SD-OCT) for three-dimensional (3D) retinal imaging of small animals and quantitative retinal information extraction using 3D segmentation of the OCT images. METHODS: A high-resolution SD-OCT system was built for in vivo imaging of rodent retina. OCT fundus images similar to those acquired with a scanning laser ophthalmoscope (SLO) were constructed from the measured OCT data, which provided precise spatial registration of the OCT cross-sectional images on the fundus. A 3D segmentation algorithm was developed for calculation of the retinal thickness map. OCT images were compared by histologic examination. RESULTS: High-quality OCT images of the retinas of mice (B6/SJLF2 for normal retina, rhodopsin-deficient Rho(-/-) for photoreceptor degeneration, and LH(BETA)T(AG) for retinoblastoma) and rat (Wistar) were acquired. The OCT images compared well with histology. Not only was a 3D image of the tumor in a retinoblastoma mouse model successfully imaged in vivo but the tumor volume was extracted from the 3D image. Retinal thickness maps were calculated that enabled successful quantitative comparison of the retinal thickness distribution between the normal (202.3 +/- 9.3 microm) and the degenerative (102.7 +/- 12.6 microm) mouse retina. CONCLUSIONS: High-resolution spectral-domain OCT provides unprecedented high-quality 2D and 3D in vivo visualization of retinal structures of mouse and rat models of retinal diseases. With the capability of 3D quantitative information extraction and precise spatial registration, the OCT system made possible longitudinal study of ocular diseases that has been impossible to conduct.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.06-0815

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Ruggeri, M., Wehbe, H., Jiao, S., Gregori, G., Jockovich, M. E., Hackam, A., Duan, Y., & Puliafito, C. A.
Venue
Investigative Opthalmology & Visual Science
Published
2007-04-01
Volume
48
Issue
4
Pages
1808
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2059495986
Cited by
215
References
3
FWCI
11.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.