CoChat

Multiplex Bead Analysis of Vitreous Humor of Patients with Vitreoretinal Disorders

Banerjee, Somnath, Savant, Vijay, Scott, Robert A. H., Curnow, S. John, Wallace, Graham R., Murray, Philip I. · 2007 · Investigative Opthalmology & Visual Science
Cited by 128

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

PURPOSE: Vitreoretinal disorders are frequently characterized by increased vitreous levels of cellular mediators, including cytokines, chemokines, and growth factors. The study was conducted to investigate whether multiplex bead analysis could identify disease-specific profiles of these mediators in a variety of vitreoretinal diseases. METHODS: Levels of 19 mediators were measured: the cytokines IL-6, IL-10, IL-12, IL-13, IL-15, IL-17, TNF, IFN-gamma, granulocyte-macrophage-colony-stimulating factor (GM-CSF), and granulocyte-stimulating factor (G-CSF); the chemokines CCL2, CCL3, CCL4, CCL5, CCL11, and CXCL8; and the growth factors epidermal growth factor (EGF), FGF, and VEGF, by using multiplex bead analysis of vitreous humor of 58 eyes undergoing vitrectomy for a variety of vitreoretinal disorders. RESULTS: The predominant mediators detected were IL-6, CXCL8, and CCL2. The most complex pattern of mediators was seen in patients with proliferative vitreoretinopathy (PVR) and included a mixture of cytokines, chemokines, and growth factors. Patients with chronic uveitis showed a limited mediator pattern that did not suggest either a Th1 or Th2 response. By comparison, patients with lens-induced uveitis (LIU) showed significantly greater levels of cytokines than did patients with chronic uveitis, including IFN-gamma and IL-12, with a trend toward an acute Th1 inflammatory response. Moreover, in samples from patients with LIU, CXCL8 inversely correlated with time after initial surgery and duration of treatment. CONCLUSIONS: Multiplex bead analysis allows the measurement of multiple mediators from a single vitreous sample. The data confirm patterns of mediators previously described in different vitreoretinal conditions. In addition, LIU mediator levels correlate with duration of treatment and time after cataract surgery.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.06-1358

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 128

Metadata

Authors
Banerjee, S., Savant, V., Scott, R. A. H., Curnow, S. J., Wallace, G. R., & Murray, P. I.
Venue
Investigative Opthalmology & Visual Science
Published
2007-05-01
Volume
48
Issue
5
Pages
2203
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2092509198
Cited by
128
References
1
FWCI
7.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.