CoChat

A Comparison of Fundus Autofluorescence and Retinal Structure in Patients with Stargardt Disease

Open access
Gomes, Nuno L., Greenstein, Vivienne C., Carlson, Joshua N., Tsang, Stephen H., Smith, R. Theodore, Carr, Ronald E., Hood, Donald C., Chang, Stanley · 2009 · Investigative Opthalmology & Visual Science
Cited by 148

The DOI matches its Crossref record.

Abstract

PURPOSE: To improve the understanding of Stargardt disease by comparing structural changes seen on spectral domain optical coherence tomography (SD-OCT) to those visible on fundus autofluorescence (FAF). METHODS: FAF and SD-OCT were performed on 22 eyes of 11 patients with Stargardt disease. SD-OCT images were obtained at the fovea and at the eccentric preferred retinal locus (PRL). The diameters of absent (hypoautofluorescence) and abnormal FAF areas were measured. The extent of the transverse defect of the junction between the inner and outer segments of the photoreceptors (IS-OS) was measured in the foveal area. The PRL was evaluated with fundus photography and microperimetry. RESULTS: Twenty-one of 22 eyes showed defective FAF. In 17 eyes, FAF was absent in the fovea and in four eyes, FAF was abnormal. All eyes showed disorganization and/or loss of the IS-OS junction in the foveal area on SD-OCT. The diameter of the absent FAF area was smaller than the measurement of the IS-OS junction loss; the latter was closer to the diameter of the abnormal FAF area. Seventeen eyes had an eccentric PRL associated with a retinal area with no defects on FAF. CONCLUSIONS: In the majority of eyes, changes shown by SD-OCT correlated well with changes in FAF. However, in three patients, photoreceptor abnormalities were seen in the fovea on SD-OCT without an equivalent abnormality on FAF. This result suggests that in these patients, the structural integrity of the photoreceptors may be affected earlier than changes in the RPE at least as detected by FAF.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.08-2657

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Gomes, N. L., Greenstein, V. C., Carlson, J. N., Tsang, S. H., Smith, R. T., Carr, R. E., Hood, D. C., & Chang, S.
Venue
Investigative Opthalmology & Visual Science
Published
2009-08-01
Volume
50
Issue
8
Pages
3953
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2074035096
Cited by
148
References
0
FWCI
3.48
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.