The Circadian Curve of Intraocular Pressure: Can We Estimate Its Characteristics during Office Hours?
Open accessAbstract
PURPOSE: To verify whether office-hour measurements in patients in different body positions can estimate the characteristics of 24-hour intraocular pressure (IOP). METHODS: The 24-hour IOP curves of 29 healthy subjects (10 young adults, 19 elderly) and 30 patients with untreated glaucoma were analyzed. Measurements were taken at 9 AM; 12, 3, 6, and 9 PM; and 12, 3, and 6 AM, both in the supine and sitting (Goldmann tonometer) positions. Peak, mean, and fluctuation of 24-hour IOP curves were compared with office-hour measurements obtained in subjects in the sitting position alone and with combined pressures obtained in the sitting and supine positions (four measurements in each body position from 9 AM to 6 PM). The percentage of subjects with estimates of all IOP parameters within a cutoff of +/-1 (peak and mean) and +/-2 mm Hg (fluctuation) was calculated. RESULTS: Office-hour sitting measurements correctly identified peak, mean, and IOP fluctuation in 10% of the young adults, 32% of the elderly control subjects, and 20% of the patients with glaucoma, whereas the combination of supine and sitting measurements correctly identified them in 30%, 85%, and 46% of cases, respectively. It is noteworthy that office-hour measurements did not characterize any 24-hour parameter in 20% of patients with glaucoma. CONCLUSIONS: Compared with sitting measurements alone, the collection of supine and sitting office-hour measurements may enhance the correct identification of 24-hour IOP characteristics in both control subjects and untreated patients with glaucoma, thus reducing the need for obtaining 24-hour curves to a minority of patients.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The normal range for intraocular pressure is reportedly 7-21 mmHg, and daily fluctuations in intraocular pressure can show an approximate range of 3-7 mmHg.
“The normal range for IOPs is reportedly 7–21 mmHg, and daily fluctuations in IOP can show an approximate range of 3–7 mmHg [22–25].”
From Bimatoprost for Eyelash Growth in Japanese Subjects: Two Multicenter Controlled Studies (2014) · cites this paper as [25]
Cited by
Sorted by citations
Bimatoprost for Eyelash Growth in Japanese Subjects: Two Multicenter Controlled Studies
Harii, K., Arase, S., Tsuboi, R., Weng, E., Daniels, S., & VanDenburgh, A. (2014) · Aesthetic Plastic Surgery · doi:10.1007/s00266-014-0293-7 · Cited by 29 · see citing works
- Authors
- Fogagnolo, P., Orzalesi, N., Ferreras, A., & Rossetti, L.
- Affiliations
- Fondazione G.B. Bietti (IT)
- University of Milan (IT)
- Universidad de Zaragoza (ES)
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2009-05-01
- Volume
- 50
- Issue
- 5
- Pages
- 2209
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W1964388951
- Cited by
- 75
- References
- 0
- Citations by year
- 2026: 3 · 2025: 4 · 2024: 3 · 2023: 1 · 2022: 5 · 2021: 5 · 2020: 6 · 2019: 5 · 2018: 2 · 2017: 2 · 2016: 5 · 2015: 5 · 2014: 9 · 2013: 5 · 2012: 7
- FWCI
- 5.06
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- other-oa
- Locations
- Investigative Ophthalmology & Visual Science (publishedVersion)
- PubMed (publishedVersion)
- Archivio Istituzionale della Ricerca (Universita Degli Studi Di Milano) (submittedVersion, other-oa)
- Topics
- Health Sciences › Medicine › Ophthalmology › Glaucoma and retinal disorders
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Corneal surgery and disorders
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Keywords
- intraocular pressure, circadian rhythm, IOP fluctuation, untreated glaucoma, posture
- MeSH terms
- Adult, Aged, Aging, Circadian Rhythm, Female, Glaucoma, Open-Angle, Humans, Intraocular Pressure, Male, Physicians' Offices, Posture, Retrospective Studies, Tonometry, Ocular
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review