Biomechanical Properties of the Cornea in Fuchs’ Corneal Dystrophy

del Buey, Mari´a A., Cristo´bal, Jose´ A., Ascaso, Francisco J., Lavilla, Laura, Lanchares, Elena · 2009 · Investigative Opthalmology & Visual Science
Cited by 126

The DOI matches its Crossref record.

Abstract

PURPOSE: To investigate the effects of Fuchs' corneal dystrophy (FCD) on corneal biomechanical properties and the results of IOP readings in relation to changes in corneal hysteresis (CH) and central corneal thickness (CCT). METHODS: Corneal biomechanical properties, including CH, corneal resistance factor (CRF), and CCT, were measured with the ocular response analyzer (ORA) in 11 eyes of 11 patients with clinically confirmed FCD and 12 eyes of 12 healthy subjects. The ORA was also used to determine the values of intraocular pressure (IOP(g)) and corneal compensated IOP (IOP(cc)). Goldmann applanation tonometry (GAT) was also measured. RESULTS: CH measured 10.3 +/- 1.6 mm Hg (range, 8.7-13.8) in normal eyes and 6.9 +/- 1.8 mm Hg (range, 4.6-11.7) in FCD eyes (P = 0.001). CRF in the normal and FCD eyes was 10.5 +/- 1.5 mm Hg (range, 8.5-13.3) and 8.1 +/- 1.9 (range, 4.5-11.2), respectively (P = 0.005). CCT was higher in FCD eyes (606 +/- 20 microm; range, 578-635) than in normal eyes (538.4 +/- 24.9 microm; range, 495-575; P = 0.0001). IOP(g) was 16.2 +/- 2.2 mm Hg (range, 13.5-18.7) in control eyes compared with 17.6 +/- 2.7 mm Hg (range, 12.8-18.6) in FCD eyes (P = 0.201). However, IOP(cc) in the FCD group (21.8 +/- 4.6 mm Hg; range, 12.8-29.0) was higher than in the control group (16.5 +/- 3.4 mm Hg; range, 11.9-23.9; P = 0.006). GAT in the normal and FCD eyes was 16.7 +/- 2.1 mm Hg (range, 12.8-18.6) and 16.9 +/- 2.3 mm Hg (range, 13.1-19.0), respectively (P = 0.205). CONCLUSIONS: FCD led to a change of corneal biomechanical properties. CH and CRF were significantly lower in FCD eyes than in normal eyes. IOP(cc) was significantly higher in FCD eyes than in control eyes. These values may be useful in addition to CCT when assessing corneal rigidity. Thus, FCD may cause an underestimation error in IOP measurement.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.08-3312

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
del Buey, M. A., Cristo´bal, J. A., Ascaso, F. J., Lavilla, L., & Lanchares, E.
Venue
Investigative Opthalmology & Visual Science
Published
2009-07-01
Volume
50
Issue
7
Pages
3199
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2064479806
Cited by
126
References
0
FWCI
7.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.