Abstract

PURPOSE: To examine retinal function using the full-field electroretinogram (ERG) during and after acute intraocular pressure (IOP) elevation in wild-type mice. METHODS: IOP was elevated by anterior chamber cannulation in wild-type C57/BL6 mice. The pressure-function relationship was determined by IOP elevation in steps from baseline to 80 mm Hg. The rate of functional recovery was assessed for 60 minutes after an IOP spike of 50 mm Hg for 30 minutes. During and immediately after IOP elevation, scotopic ERG signals were recorded in response to dim and bright flashes (-4.54, -2.23, and 0.34 log cd x s x m(-2)) and analyzed for photoreceptoral (a-wave), ON-bipolar (b-wave), oscillatory potentials (OPs), and scotopic threshold responses (positive [p]STR/negative [n] STR). A full ERG protocol was collected 2 days before and 7 days after the single 50-mm Hg IOP spike. RESULTS: The pSTR was most sensitive to IOP elevation with 50% amplitude loss (mu) at 41 mm Hg (mu, 95% confidence limits (CL): 37.7, 45.6) followed by nSTR at 45 mm Hg (95% CL: 41.0, 49.1). pSTR was significantly more sensitive than the b-wave (95% CL: 41.4, 49.1), a-wave (95% CL: 47.6, 55.3), and OPs (95% CL: 49.6, 59.2). pSTR showed slower recovery immediately after the 50 mm Hg spike compared with the b-wave (P = 0.02). One week after the 50-mm Hg spike, pSTR (-30% +/- 6%, P < 0.001) and OP (-27% +/- 2%, P < 0.001) amplitudes were reduced, whereas other components were unaffected. CONCLUSIONS: The STR in mice is more sensitive to acute IOP elevation and recovers slower than other ERG components. Reduction in pSTR and OP amplitude at 1 week suggests persistent impairment of inner retinal function can occur after a single IOP spike.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.09-3814

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 80

Metadata

Authors
Kong, Y. X., Crowston, J. G., Vingrys, A. J., Trounce, I. A., & Bui, B. V.
Venue
Investigative Opthalmology & Visual Science
Published
2009-12-01
Volume
50
Issue
12
Pages
5732
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2168531200
Cited by
80
References
2
FWCI
4.12
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Functional Changes in the Retina during and after Acute Intraocular Pressure Elevation in Mice. https://app.cochat.ai/papers/10.1167/iovs.09-3814
The paper
Kong, Y. X., Crowston, J. G., Vingrys, A. J., Trounce, I. A., & Bui, B. V. (2009). Functional Changes in the Retina during and after Acute Intraocular Pressure Elevation in Mice. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.09-3814

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.