Formation and Disassembly of Adherens and Tight Junctions in the Corneal Endothelium: Regulation by Actomyosin Contraction
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Purpose. To determine the role of actin cytoskeleton in the disassembly and reformation of adherens junctions (AJs) and tight junctions (TJs) in bovine corneal endothelial monolayers. Methods. Disassembly and reformation of AJs and TJs were induced by extracellular Ca(2+) depletion and subsequent add-back of Ca(2+), respectively. Resultant changes in the transendothelial electrical resistance (TER), an indicator of integrity of TJs, were measured based on electrical cell-substrate impedance. Phosphorylated myosin light chain (ppMLC), a biochemical measure of actomyosin contraction, and activation of its upstream regulatory molecule RhoA-GTP were assessed by Western blot analysis. Results. Extracellular Ca(2+) depletion led to activation of RhoA, increase in ppMLC, decrease in TER, contraction of the perijunctional actomyosin ring (PAMR), and redistribution of zonula occludens-1 (ZO-1) and cadherins. These effects were reversed on Ca(2+) add-back. Pretreatment with Y-27632 and blebbistatin (as inhibitors of actomyosin contraction) reduced the rate of decline in TER, opposed the contraction of the PAMR, and blocked the redistribution of ZO-1 and cadherins. Both drugs reduced the recovery in TER and opposed the normal redistribution of ZO-1 and cadherins on Ca(2+) add-back. Cytochalasin D, which led to dissolution of the PAMR, also reduced the recovery of TER on Ca(2+) add-back. Conclusions. The (Ca(2+) depletion)-induced disassembly of AJs accelerates the breakdown of TJs through a concomitant increase in the actomyosin contraction of the PAMR. However, these data on reassembly show that a contractile tone of the PAMR is essential for assembly of the apical junctional complex.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fanning, A. S., Jameson, B. J., Jesaitis, L. A., & Anderson, J. M. (1998) · Journal of Biological Chemistry · doi:10.1074/jbc.273.45.29745 · Cited by 1,432
Directed Actin Polymerization Is the Driving Force for Epithelial Cell–Cell Adhesion
Vasioukhin, V., Bauer, C., Yin, M., & Fuchs, E. (2000) · Cell · doi:10.1016/s0092-8674(00)81559-7 · Cited by 1,205
Gumbiner, B., Stevenson, B., & Grimaldi, A. (1988) · The Journal of cell biology · doi:10.1083/jcb.107.4.1575 · Cited by 799
Myosin light chain phosphorylation regulates barrier function by remodeling tight junction structure
Shen, L., Black, E. D., Witkowski, E. D., Lencer, W. I., Guerriero, V., Schneeberger, E. E., & Turner, J. R. (2006) · Journal of Cell Science · doi:10.1242/jcs.02915 · Cited by 467
Cited by
The Hippo pathway: regulators and regulations.
Yu, F.-X., & Guan, K.-L. (2013) · Genes & Development · doi:10.1101/gad.210773.112 · Cited by 1,231
Molecular mechanisms underlying the corneal endothelial pump
Bonanno, J. A. (2012) · Experimental Eye Research · doi:10.1016/j.exer.2011.06.004 · Cited by 408
Dynamic Regulation of Barrier Integrity of the Corneal Endothelium
Srinivas, S. P. (2010) · Optometry and Vision Science · doi:10.1097/opx.0b013e3181d39464 · Cited by 161
Self-citationSong, E. S., Park, J.-H., Ha, S. S., Cha, P.-H., Kang, J.-T., Park, C. Y., & Park, K. (2022) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.2c01709 · Cited by 25
Han, B., Zhang, R., Li, L., Hu, C., Li, M., Liu, J., Sun, X., Fan, W., Xie, J., & Lei, Y. (2023) · Journal of Materials Chemistry B · doi:10.1039/d3tb01430d · Cited by 11
Metadata
- Authors
- Ramachandran, C., & Srinivas, S. P.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2010-04-01
- Volume
- 51
- Issue
- 4
- Pages
- 2139
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2091430959
- Cited by
- 45
- References
- 4
- FWCI
- 2.12
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.