The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Optical Coherence Tomography May Be Used to Predict Visual Acuity in Patients with Macular Edema
Abstract
PURPOSE: To determine whether the volume of retinal tissue passing between the inner and outer retina in macular edema could be used as an indicator of visual acuity. METHODS: Diabetic and uveitic patients with cystoid macular edema (81 subjects, 129 eyes) were recruited. Best corrected logMAR visual acuity and spectral optical coherence tomography (OCT/SLO; OTI, Toronto, ONT, Canada) were performed in all patients. Coronal OCT scans obtained from a cross section of the retina between the plexiform layers were analyzed with a grid of five concentric radii (500, 1000, 1500, 2000, and 2500 μm centered on the fovea). The images were analyzed to determine the amount of retinal tissue present within each ring. A linear regression model was developed to determine the relationship between tissue integrity and logMAR visual acuity. RESULTS: A linear relationship between tissue integrity and VA was demonstrated. The volume of retinal tissue between the plexiform layers in rings 1 and 2 (up to 1000 μm from the foveal center) predicted 80% of visual acuity. By contrast, central macular thickness within the central 1000 μm predicted only 14% of visual acuity. CONCLUSIONS: This study showed that the cross-sectional area of retinal tissue between the plexiform layers in cystoid macular edema, as imaged by OCT, is the best indicator of visual function at baseline. Further prospective treatment trials are needed to investigate this parameter as a predictor of visual outcome after intervention.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Cited by
Schmidt-Erfurth, U., Garcia-Arumi, J., Bandello, F., Berg, K., Chakravarthy, U., Gerendas, B. S., Jonas, J., Larsen, M., Tadayoni, R., & Loewenstein, A. (2017) · Ophthalmologica · doi:10.1159/000458539 · Cited by 703
Sun, J. K., Lin, M. M., Lammer, J., Prager, S., Sarangi, R., Silva, P. S., & Aiello, L. P. (2014) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2014.2350 · Cited by 574
A paradigm shift in imaging biomarkers in neovascular age-related macular degeneration
Schmidt-Erfurth, U., & Waldstein, S. M. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.07.007 · Cited by 390
Zur, D., Iglicki, M., Busch, C., Invernizzi, A., Mariussi, M., Loewenstein, A., Busch, C., Cebeci, Z., Chhablani, J. K., Chaikitmongkol, V., et al. (2018) · Ophthalmology · doi:10.1016/j.ophtha.2017.08.031 · Cited by 271
Metadata
- Authors
- Pelosini, L., Hull, C. C., Boyce, J. F., McHugh, D., Stanford, M. R., & Marshall, J.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2011-04-25
- Volume
- 52
- Issue
- 5
- Pages
- 2741
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2020281235
- Cited by
- 208
- References
- 2
- FWCI
- 4.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.