The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
The Post-Illumination Pupil Response Is Reduced in Glaucoma Patients
Open accessAbstract
PURPOSE: The post-illumination pupil response (PIPR), which is driven by the intrinsic response of melanopsin-containing, intrinsically photosensitive retinal ganglion cells, has previously been characterized in healthy eyes. The present study examined whether the PIPR is affected in patients with glaucoma compared with healthy subjects. METHODS: Sixteen glaucoma patients (mean age, 63.7 years) were tested by presenting a 60°, 10-second light stimulus (13 log quanta/cm(2)/s retinal irradiance) of either 470 nm (blue) or 623 nm (red) to one eye after dilation. The consensual pupil response of the fellow undilated eye was recorded by infrared pupillometry for 50 seconds after light offset. These pupillary responses were compared with those of 19 age-matched controls (mean age, 59 years). RESULTS: The glaucoma patients displayed a net PIPR (blue PIPR minus red PIPR) that was significantly (t-test, P < 0.001) smaller (0.6 mm, SEM 0.12; P < 0.05) than in age-matched controls (1.3 mm, SEM 0.16; P < 0.001). For the patient population, the magnitude of the net PIPR was inversely correlated with the measured visual field loss (mean deviation) of the tested eye. CONCLUSIONS: This study demonstrates that there is a significant decrease in the ipRGC-mediated PIPR in glaucomatous patients when compared to age-matched controls. As the severity of the glaucomatous neuropathy increases, there is a correlated decrease in the PIPR. Therefore, this test has the potential for use as a clinical tool in evaluating patients with glaucoma.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Phototransduction by retinal ganglion cells that set the circadian clock
Berson, D. M., Dunn, F. A., & Takao, M. (2002) · Science · doi:10.1126/science.1067262 · Cited by 3,629
Dacey, D. M., Liao, H.-W., Peterson, B. B., Robinson, F. R., Smith, V. C., Pokorny, J., Yau, K.-W., & Gamlin, P. D. (2005) · Nature · doi:10.1038/nature03387 · Cited by 1,333
Self-citation
Cited by
Melanopsin-Positive Intrinsically Photosensitive Retinal Ganglion Cells: From Form to Function
Schmidt, T. M., Do, M. T. H., Dacey, D., Lucas, R., Hattar, S., & Matynia, A. (2011) · The Journal of Neuroscience · doi:10.1523/jneurosci.4132-11.2011 · Cited by 259
Park, J. C., Moura, A. L., Raza, A. S., Rhee, D. W., Kardon, R. H., & Hood, D. C. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-7586 · Cited by 259
Electrical induction of vision
Tehovnik, E. J., & Slocum, W. M. (2013) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2013.03.012 · Cited by 33
Sarrazin, N., Chavret-Reculon, E., Bachelin, C., Felfli, M., Arab, R., Gilardeau, S., Brazhnikova, E., Dubus, E., Yahia Cherif, L., Lorenceau, J., et al. (2022) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2115973119 · Cited by 15
Metadata
- Authors
- Kankipati, L., Girkin, C. A., & Gamlin, P. D.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2011-04-08
- Volume
- 52
- Issue
- 5
- Pages
- 2287
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2087148598
- Cited by
- 186
- References
- 2
- FWCI
- 11.08
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Post-Illumination Pupil Response Is Reduced in Glaucoma Patients. https://app.cochat.ai/papers/10.1167/iovs.10-6023
- The paper
- Kankipati, L., Girkin, C. A., & Gamlin, P. D. (2011). The Post-Illumination Pupil Response Is Reduced in Glaucoma Patients. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.10-6023
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.