CoChat

In Vivo Evaluation of Laser-Induced Choroidal Neovascularization Using Spectral-Domain Optical Coherence Tomography

Giani, Andrea, Thanos, Aristomenis, Roh, Mi In, Connolly, Edward, Trichonas, George, Kim, Ivana, Gragoudas, Evangelos, Vavvas, Demetrios, Miller, Joan W. · 2011 · Investigative Opthalmology & Visual Science
Cited by 97

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

PURPOSE: To describe the in vivo evolution of laser-induced choroidal neovascularization (CNV) in mice using spectral domain optical coherence tomography (SD-OCT). METHODS: Laser photocoagulation was applied to the mouse fundus using a 532-nm diode laser (100, 150, and 200 mW; 100-μm diameter, 0.1-second duration). SD-OCT examination was performed immediately after laser application and at days 3, 5, 7, 14, 21, and 28 after laser. Fluorescein angiography (FA) was performed at day 5, 7, 14, and 28. Acquired SD-OCT images were analyzed to describe morphologic features, measure CNV size and retinal thickness, and assess the frequency of lesions resulting in fluid accumulation. Finally, SD-OCT images were compared to fluorescein angiograms and histologic sections with immunostaining at similar time points. RESULTS: SD-OCT allowed visualization of the initial laser damage and the subsequent stages of the injury response. CNV formation reached its maximum size at day 5. By day 7, significant size reduction was observed (P < 0.001), continuing through days 14 and 28. Exudation signs, such as fluid accumulation and increase in retinal thickness, followed the same time course, with a peak at day 5 and a decrease by day 7. Delivery of higher laser energy levels to the RPE/choroid complex resulted in a significant percentage of lesions demonstrating excessive chorioretinal damage without CNV formation. CONCLUSIONS: SD-OCT is a fast and reliable tool for the in vivo evaluation of laser-induced CNV, allowing quantification of lesion size and exudation parameters. Moreover, it provides morphologic information that correlates with histologic findings.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.10-6266

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 97

Metadata

Authors
Giani, A., Thanos, A., Roh, M. I., Connolly, E., Trichonas, G., Kim, I., Gragoudas, E., Vavvas, D., & Miller, J. W.
Venue
Investigative Opthalmology & Visual Science
Published
2011-05-31
Volume
52
Issue
6
Pages
3880
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2082335148
Cited by
97
References
2
FWCI
4.71
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: In Vivo Evaluation of Laser-Induced Choroidal Neovascularization Using Spectral-Domain Optical Coherence Tomography. https://app.cochat.ai/papers/10.1167/iovs.10-6266
The paper
Giani, A., Thanos, A., Roh, M. I., Connolly, E., Trichonas, G., Kim, I., Gragoudas, E., Vavvas, D., & Miller, J. W. (2011). In Vivo Evaluation of Laser-Induced Choroidal Neovascularization Using Spectral-Domain Optical Coherence Tomography. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.10-6266

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.