CoChat

Pharmacokinetics of a Sustained-Release Dexamethasone Intravitreal Implant in Vitrectomized and Nonvitrectomized Eyes

Chang-Lin, Joan-En, Burke, James A., Peng, Qing, Lin, Ton, Orilla, Werhner C., Ghosn, Corine R., Zhang, Kai-Ming, Kuppermann, Baruch D., Robinson, Michael R., Whitcup, Scott M., Welty, Devin F. · 2011 · Investigative Opthalmology & Visual Science
Cited by 197

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

Abstract

PURPOSE: To evaluate dexamethasone pharmacokinetics after implantation of a sustained-release dexamethasone (DEX) intravitreal implant in nonvitrectomized and vitrectomized eyes. METHODS: The right eyes of 25 rabbits underwent vitrectomy; contralateral eyes served as nonvitrectomy controls. The 0.7-mg DEX implant was injected into both eyes, and drug concentrations were determined in the vitreous humor and retina for 31 days (on days 2, 8, 15, 22, and 31). RESULTS: DEX was present in nonvitrectomized and vitrectomized eyes for at least 31 days. There were no statistically significant differences in DEX concentration between nonvitrectomized and vitrectomized eyes at any time point (P > 0.05). The maximum concentration of DEX in nonvitrectomized versus vitrectomized eyes for vitreous humor was 791 ng/mL (day 22) versus 731 ng/mL (day 22), respectively, and for retina it was 4110 ng/mL (day 15) versus 3670 ng/mL (day 22), respectively. Mean absorption (AUC(0-tlast)) of dexamethasone in nonvitrectomized and vitrectomized eyes was not different for both the vitreous humor (13,600 vs. 15,000 ng/day/mL; P = 0.73) and retina (67,600 vs. 50,200 ng/day/mL; P = 0.47). CONCLUSIONS: The vitreoretinal pharmacokinetic profiles were similar between nonvitrectomized and vitrectomized eyes. These observations are consistent with clinical findings of the DEX implant in patients who have undergone vitrectomy and should reduce concerns about the use of the DEX implant in eyes that have undergone vitrectomy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.10-6387

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 197

Metadata

Authors
Chang-Lin, J.-E., Burke, J. A., Peng, Q., Lin, T., Orilla, W. C., Ghosn, C. R., Zhang, K.-M., Kuppermann, B. D., Robinson, M. R., Whitcup, S. M., & Welty, D. F.
Venue
Investigative Opthalmology & Visual Science
Published
2011-06-28
Volume
52
Issue
7
Pages
4605
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2076976601
Cited by
197
References
30
FWCI
6.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.