CoChat

Blink Frequency and Duration during Perimetry and Their Relationship to Test–Retest Threshold Variability

Open access
Wang, Yanfang, Toor, Sonia S., Gautam, Ramesh, Henson, David B. · 2011 · Investigative Opthalmology & Visual Science
Cited by 59

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

PURPOSE: To describe different patterns of blinking in patients undergoing a visual field test and to establish whether the blink parameters are related to threshold variability. METHODS: Thirty-nine patients with diagnosed or suspected glaucoma were recruited to undertake a perimetric task twice. Blinks were detected with a video eye-tracker system that records at a sampling rate of 60 Hz. Blink frequency, duration, and episodes of microsleep (eye closures >500 ms) were analyzed, and correlated with test-retest threshold variability. The timing of blinks with respect to stimulus presentation was analyzed and the percentage of seen stimuli for all presentations (POS(overall)) and those overlapped with blinks (POS(overlapped)) were compared. RESULTS: Blink frequency ranged from 0 to 58 per minute. A significant increase in blink frequency was observed in the second test (P < 0.001), whereas blink duration and microsleep episodes were not significantly different between the two tests. The relationship between test-retest threshold variability and all blink parameters was not significant. For suprathreshold stimulus presentations, blinks often occurred after presentation, whereas for subthreshold presentations, their timing was independent of stimulus timing. The difference between POS(overall) and POS(overlapped) was significant (P < 0.001), and a slight decrease in POS(overlapped) was observed with the increase of overlap duration. CONCLUSIONS: A wide range of blink frequencies was observed during perimetric testing. Although no blink parameters showed significant influence on threshold variability, when the blinks overlapped with a stimulus presentation, the probability of seeing was reduced. For suprathreshold stimuli, blinks often occurred after the presentation, whereas for subthreshold presentations, there was no relationship to presentation time.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.10-6553

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 59

Metadata

Authors
Wang, Y., Toor, S. S., Gautam, R., & Henson, D. B.
Venue
Investigative Opthalmology & Visual Science
Published
2011-06-28
Volume
52
Issue
7
Pages
4546
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2075373176
Cited by
59
References
2
FWCI
0.28
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Blink Frequency and Duration during Perimetry and Their Relationship to Test–Retest Threshold Variability. https://app.cochat.ai/papers/10.1167/iovs.10-6553
The paper
Wang, Y., Toor, S. S., Gautam, R., & Henson, D. B. (2011). Blink Frequency and Duration during Perimetry and Their Relationship to Test–Retest Threshold Variability. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.10-6553

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.