The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Variation of Cone Photoreceptor Packing Density with Retinal Eccentricity and Age
Open accessAbstract
PURPOSE: To study the variation of cone photoreceptor packing density across the retina in healthy subjects of different ages. METHODS: High-resolution adaptive optics scanning laser ophthalmoscope (AOSLO) systems were used to systematically image the retinas of two groups of subjects of different ages. Ten younger subjects (age range, 22-35 years) and 10 older subjects (age range, 50-65 years) were tested. Strips of cone photoreceptors, approximately 12° × 1.8° long were imaged for each of the four primary retinal meridians: superior, inferior, nasal, and temporal. Cone photoreceptors within the strips were counted, and cone photoreceptor packing density was calculated. Statistical analysis (three-way ANOVA) was used to calculate the interaction for cone photoreceptor packing density between age, meridian, and eccentricity. RESULTS: As expected, cone photoreceptor packing density was higher close to the fovea and decreased with increasing retinal eccentricity from 0.18 to 3.5 mm (∼0.6-12°). Older subjects had approximately 75% of the cone density at 0.18 mm (∼0.6°), and this difference decreased rapidly with eccentricity, with the two groups having similar cone photoreceptor packing densities beyond 0.5 mm retinal eccentricity on average. CONCLUSIONS: Cone packing density in the living human retina decreases as a function of age within the foveal center with the largest difference being found at our most central measurement site. At all ages, the retina showed meridional difference in cone densities, with cone photoreceptor packing density decreasing faster with increasing eccentricity in the vertical dimensions than in the horizontal dimensions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Human photoreceptor topography
Curcio, C. A., Sloan, K. R., Kalina, R. E., & Hendrickson, A. E. (1990) · Journal of Comparative Neurology · doi:10.1002/cne.902920402 · Cited by 2,790
Supernormal vision and high-resolution retinal imaging through adaptive optics
Liang, J., Williams, D. R., & Miller, D. T. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.002884 · Cited by 1,454
Adaptive optics scanning laser ophthalmoscopy
Roorda, A., Romero-Borja, F., Donnelly III, W. J., Queener, H., Hebert, T. J., & Campbell, M. C. W. (2002) · Optics Express · doi:10.1364/oe.10.000405 · Cited by 967
Improvements on Littmann's method of determining the size of retinal features by fundus photography
Bennett, A. G., Rudnicka, A. R., & Edgar, D. F. (1994) · Graefe's Archive for Clinical and Experimental Ophthalmology · doi:10.1007/bf00175988 · Cited by 693
Curcio, C. A., Millican, C. L., Allen, K. A., & Kalina, R. E. (1993) · PubMed · Cited by 678
(1992) · PubMed · Cited by 604
Distribution of Cones in Human and Monkey Retina: Individual Variability and Radial Asymmetry
Curcio, C. A., Sloan, K. R., Packer, O., Hendrickson, A. E., & Kalina, R. E. (1987) · Science · doi:10.1126/science.3576186 · Cited by 585
The Morphological Development of the Human Fovea
Hendrickson, A. E., & Yuodelis, C. (1984) · Ophthalmology · doi:10.1016/s0161-6420(84)34247-6 · Cited by 556
Analysis of the macular pigment by HPLC: retinal distribution and age study.
Bone, R. A., Landrum, J. T., Fernandez, L., & Tarsis, S. L. (1988) · PubMed · Cited by 527
The chromatic eye: a new reduced-eye model of ocular chromatic aberration in humans
Thibos, L. N., Ye, M., Zhang, X., & Bradley, A. (1992) · Applied Optics · doi:10.1364/ao.31.003594 · Cited by 309
Cited by
Adaptation of the central retina for high acuity vision: Cones, the fovea and the avascular zone
Provis, J. M., Dubis, A. M., Maddess, T., & Carroll, J. (2013) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2013.01.005 · Cited by 298
Adaptive optics imaging of the human retina
Burns, S. A., Elsner, A. E., Sapoznik, K. A., Warner, R. L., & Gast, T. J. (2019) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.08.002 · Cited by 263
Self-citationWatson, A. B. (2014) · Journal of Vision · doi:10.1167/14.7.15 · Cited by 197
Metadata
- Authors
- Song, H., Chui, T. Y. P., Zhong, Z., Elsner, A. E., & Burns, S. A.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2011-09-20
- Volume
- 52
- Issue
- 10
- Pages
- 7376
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2060336605
- Cited by
- 267
- References
- 36
- FWCI
- 11.03
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Variation of Cone Photoreceptor Packing Density with Retinal Eccentricity and Age. https://app.cochat.ai/papers/10.1167/iovs.11-7199
- The paper
- Song, H., Chui, T. Y. P., Zhong, Z., Elsner, A. E., & Burns, S. A. (2011). Variation of Cone Photoreceptor Packing Density with Retinal Eccentricity and Age. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.11-7199
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.