The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Brillouin Optical Microscopy for Corneal Biomechanics
Open accessAbstract
PURPOSE: The mechanical properties of corneal tissue are linked to prevalent ocular diseases and therapeutic procedures. Brillouin microscopy is a novel optical technology that enables three-dimensional mechanical imaging. In this study, the feasibility of this noncontact technique was tested for in situ quantitative assessment of the biomechanical properties of the cornea. METHODS: Brillouin light-scattering involves a spectral shift proportional to the longitudinal modulus of elasticity of the tissue. A 532-nm single-frequency laser and a custom-developed ultrahigh-resolution spectrometer were used to measure the Brillouin frequency. Confocal scanning was used to perform Brillouin elasticity imaging of the corneas of whole bovine eyes. The longitudinal modulus of the bovine corneas was compared before and after riboflavin corneal collagen photo-cross-linking. The Brillouin measurements were then compared with conventional stress-strain mechanical test results. RESULTS: High-resolution Brillouin images of the cornea were obtained, revealing a striking depth-dependent variation of the elastic modulus across the cornea. Along the central axis, the Brillouin frequency shift varied gradually from 8.2 GHz in the epithelium to 7.5 GHz near the endothelium. The coefficients of the down slope were measured to be approximately 1.09, 0.32, and 2.94 GHz/mm in the anterior, posterior, and innermost stroma, respectively. On riboflavin collagen cross-linking, marked changes in the axial Brillouin profiles (P < 0.001) were noted before and after cross-linking. CONCLUSIONS: Brillouin imaging can assess the biomechanical properties of cornea in situ with high spatial resolution. This novel technique has the potential for use in clinical diagnostics and treatment monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evaluating Corneal Collagen Organization Using High-Resolution Nonlinear Optical Macroscopy
Jester, J. V., Winkler, M., Jester, B. E., Nien, C., Chai, D., & Brown, D. J. (2010) · Eye & Contact Lens: Science & Clinical Practice · doi:10.1097/icl.0b013e3181ee8992 · Cited by 64
Cited by
Scarcelli, G., Polacheck, W. J., Nia, H. T., Patel, K., Grodzinsky, A. J., Kamm, R. D., & Yun, S. H. (2015) · Nature Methods · doi:10.1038/nmeth.3616 · Cited by 432
Self-citation
Metadata
- Authors
- Scarcelli, G., Pineda, R., & Yun, S. H.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2012-01-20
- Volume
- 53
- Issue
- 1
- Pages
- 185
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W1969408393
- Cited by
- 354
- References
- 1
- FWCI
- 6.89
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Brillouin Optical Microscopy for Corneal Biomechanics. https://app.cochat.ai/papers/10.1167/iovs.11-8281
- The paper
- Scarcelli, G., Pineda, R., & Yun, S. H. (2012). Brillouin Optical Microscopy for Corneal Biomechanics. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.11-8281
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.