Quantitative Measurements of Autofluorescence with the Scanning Laser Ophthalmoscope
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
PURPOSE: To evaluate the feasibility and reliability of a standardized approach for quantitative measurements of fundus autofluorescence (AF) in images obtained with a confocal scanning laser ophthalmoscope (cSLO). METHODS: AF images (30°) were acquired in 34 normal subjects (age range, 20-55 years) with two different cSLOs (488-nm excitation) equipped with an internal fluorescent reference to account for variable laser power and detector sensitivity. The gray levels (GLs) of each image were calibrated to the reference, the zero GL, and the magnification, to give quantified autofluorescence (qAF). Images from subjects and fixed patterns were used to test detector linearity with respect to fluorescence intensity, the stability of qAF with change in detector gain, field uniformity, effect of refractive error, and repeatability. RESULTS: qAF was independent of detector gain and laser power over clinically relevant ranges, provided that detector gain was adjusted to maintain exposures within the linear detection range (GL < 175). Field uniformity was better than 5% in a central 20°-diameter circle but decreased more peripherally. The theoretical inverse square magnification correction was experimentally verified. Photoreceptor bleaching for at least 20 seconds was performed. Repeatability (95% confidence interval) for same day and different-day retests of qAF was ±6% to ±14%. Agreement (95% confidence interval) between the two instruments was <11%. CONCLUSIONS: Quantitative AF imaging appears feasible. It may enhance understanding of retinal degeneration, serve as a diagnostic aid and as a sensitive marker of disease progression, and provide a tool to monitor the effects of therapeutic interventions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Weng, J., Mata, N. L., Azarian, S. M., Tzekov, R. T., Birch, D. G., & Travis, G. H. (1999) · Cell · doi:10.1016/s0092-8674(00)80602-9 · Cited by 881
RPE lipofuscin and its role in retinal pathobiology
Sparrow, J. R., & Boulton, M. (2005) · Experimental Eye Research · doi:10.1016/j.exer.2005.01.007 · Cited by 644
Self-citationBiosynthetic Studies of A2E, a Major Fluorophore of Retinal Pigment Epithelial Lipofuscin
Ben-Shabat, S., Parish, C. A., Vollmer, H. R., Itagaki, Y., Fishkin, N., Nakanishi, K., & Sparrow, J. R. (2002) · Journal of Biological Chemistry · doi:10.1074/jbc.m108981200 · Cited by 214
Self-citation
Cited by
The bisretinoids of retinal pigment epithelium
Sparrow, J. R., Gregory-Roberts, E., Yamamoto, K., Blonska, A., Ghosh, S. K., Ueda, K., & Zhou, J. (2012) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2011.12.001 · Cited by 392
“Progress has been made in the implementation of methods to quantify fundus autofluorescence so as to correlate levels of fundus autofluorescence with disease severity (Delori et al., 2011).”
BackgroundResultSelf-citationCremers, F. P. M., Lee, W., Collin, R. W. J., & Allikmets, R. (2020) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2020.100861 · Cited by 315
Zanzottera, E. C., Messinger, J. D., Ach, T., Smith, R. T., Freund, K. B., & Curcio, C. A. (2015) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.15-16431 · Cited by 164
Self-citationSyndromic retinitis pigmentosa.
Karuntu, J. S., Almushattat, H., Nguyen, X.-T.-A., Plomp, A. S., Wanders, R. J. A., Hoyng, C. B., van Schooneveld, M. J., Schalij-Delfos, N. E., Brands, M. M., Leroy, B. P., et al. (2025) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2024.101324 · Cited by 39
Metadata
- Authors
- Delori, F., Greenberg, J. P., Woods, R. L., Fischer, J., Duncker, T., Sparrow, J., & Smith, R. T.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2011-12-09
- Volume
- 52
- Issue
- 13
- Pages
- 9379
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W1992364186
- Cited by
- 243
- References
- 4
- FWCI
- 9.65
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.