CoChat

Macular Function in Macular Degenerations: Repeatability of Microperimetry as a Potential Outcome Measure for ABCA4-Associated Retinopathy Trials

Open access
Cideciyan, Artur V., Swider, Malgorzata, Aleman, Tomas S., Feuer, Willam J., Schwartz, Sharon B., Russell, Robert C., Steinberg, Janet D., Stone, Edwin M., Jacobson, Samuel G. · 2012 · Investigative Opthalmology & Visual Science
Cited by 118

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

PURPOSE: To measure macular visual function in patients with unstable fixation, to define the photoreceptor source of this function, and to estimate its test-retest repeatability as a prerequisite to clinical trials. METHODS: Patients (n = 38) with ABCA4-associated retinal degeneration (RD) or with retinitis pigmentosa (RP) were studied with retina-tracking microperimetry along the foveo-papillary profile between the fovea and the optic nerve head, and point-by-point test-retest repeatability was estimated. A subset with foveal fixation was also studied with dark-adapted projection perimetry using monochromatic blue and red stimuli along the horizontal meridian. RESULTS: Macular function in ABCA4-RD patients transitioned from lower sensitivity at the parafovea to higher sensitivity in the perifovea. RP patients had the inverse pattern. Red-on-red microperimetric sensitivities successfully avoided ceiling effects and were highly correlated with absolute sensitivities. Point-by-point test-retest limits (95% confidence intervals) were ±4.2 dB; repeatability was not related to mean sensitivity, eccentricity from the fovea, age, fixation location, or instability. Repeatability was also not related to the local slope of sensitivity and was unchanged in the parapapillary retina. CONCLUSIONS: Microperimetry allows reliable testing of macular function in RD patients without foveal fixation in longitudinal studies evaluating natural disease progression or efficacy of therapeutic trials. A single estimate of test-retest repeatability can be used to determine significant changes in visual function at individual retinal loci within diseased regions that are homogeneous and those that are heterogeneous and also in transition zones at high risk for disease progression.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.11-8415

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 118

Metadata

Authors
Cideciyan, A. V., Swider, M., Aleman, T. S., Feuer, W. J., Schwartz, S. B., Russell, R. C., Steinberg, J. D., Stone, E. M., & Jacobson, S. G.
Venue
Investigative Opthalmology & Visual Science
Published
2012-02-21
Volume
53
Issue
2
Pages
841
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2026892598
Cited by
118
References
9
FWCI
3.02
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Macular Function in Macular Degenerations: Repeatability of Microperimetry as a Potential Outcome Measure for ABCA4-Associated Retinopathy Trials. https://app.cochat.ai/papers/10.1167/iovs.11-8415
The paper
Cideciyan, A. V., Swider, M., Aleman, T. S., Feuer, W. J., Schwartz, S. B., Russell, R. C., Steinberg, J. D., Stone, E. M., & Jacobson, S. G. (2012). Macular Function in Macular Degenerations: Repeatability of Microperimetry as a Potential Outcome Measure for ABCA4-Associated Retinopathy Trials. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.11-8415

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.