Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 201

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Pharmacokinetics of Ranibizumab in Patients with Neovascular Age-Related Macular Degeneration: A Population Approach

Xu, Lu, Lu, Tong, Tuomi, Lisa, Jumbe, Nelson, Lu, Jianfeng, Eppler, Steve, Kuebler, Peter, Damico-Beyer, Lisa A., Joshi, Amita · 2013 · Investigative Opthalmology & Visual Science

Abstract

PURPOSE: To characterize ranibizumab pharmacokinetics in patients with AMD. METHODS: A population approach of nonlinear mixed-effect pharmacokinetic modeling based on concentration-time data from 2993 serum samples from 674 AMD patients enrolled in 5 phase 1 to 3 clinical trials of single or multiple intravitreal (ITV) doses of ranibizumab (0.3-2.0 mg/eye) administered biweekly or monthly for up to 24 months. RESULTS: A TOTAL OF 696 CONCENTRATION-TIME RECORDS FROM 229 SUBJECTS WITH ONE OR MORE MEASURABLE TOTAL SERUM RANIBIZUMAB CONCENTRATIONS WERE ANALYZED. THE SYSTEMIC CONCENTRATION-TIME DATA FOR RANIBIZUMAB WERE BEST DESCRIBED BY A ONE-COMPARTMENT MODEL WITH FIRST-ORDER ABSORPTION INTO AND FIRST-ORDER ELIMINATION FROM THE SYSTEMIC CIRCULATION. VITREOUS ELIMINATION HALF-LIFE (T1/2) WAS CALCULATED TO BE 9 DAYS AND THE INTRINSIC SYSTEMIC ELIMINATION T1/2 WAS CALCULATED TO BE APPROXIMATELY 2 HOURS. FOLLOWING ITV ADMINISTRATION, RANIBIZUMAB EGRESSES SLOWLY INTO THE SYSTEMIC CIRCULATION, RESULTING IN AN APPARENT SERUM T1/2 OF 9 DAYS. SYSTEMIC-TO-VITREOUS EXPOSURE RATIO WAS ESTIMATED TO BE 1: 90,000. With monthly and quarterly ITV regimens, the serum concentrations of ranibizumab at steady-state for both the 0.3 and 0.5 mg/eye dose levels were estimated to be below the range needed to inhibit VEGF-A-induced endothelial cell proliferation in vitro by 50% at all times. CONCLUSIONS: Systemic exposure to ranibizumab after ITV injection was very low due to elimination on reaching systemic circulation from the vitreous. Population pharmacokinetic analysis of data from a representative sample of AMD patients did not identify clinically significant sources or correlates of variability in ranibizumab exposure. (ClinicalTrials.gov numbers, NCT00056836, NCT00056823.).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.12-10260

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 201

Metadata

Authors
Xu, L., Lu, T., Tuomi, L., Jumbe, N., Lu, J., Eppler, S., Kuebler, P., Damico-Beyer, L. A., & Joshi, A.
Venue
Investigative Opthalmology & Visual Science
Published
2013-03-05
Volume
54
Issue
3
Pages
1616
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2081930185
Cited by
201
References
5
FWCI
17.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.