CoChat

Two-Year Intraocular Delivery of Ciliary Neurotrophic Factor by Encapsulated Cell Technology Implants in Patients with Chronic Retinal Degenerative Diseases

Kauper, Konrad, McGovern, Cahil, Sherman, Sandy, Heatherton, Pam, Rapoza, Rob, Stabila, Paul, Dean, Brenda, Lee, Alice, Borges, Suzanna, Bouchard, Bruce, Tao, Weng · 2012 · Investigative Opthalmology & Visual Science
Cited by 192

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

PURPOSE: To evaluate the pharmacokinetics of ciliary neurotrophic factor (CNTF) delivered over a period of up to 2 years by an intraocular encapsulated cell technology (ECT) implant in patients with retinitis pigmentosa (RP) and geographic atrophy (GA). METHODS: Patients from phase 1 RP (CNTF1); phase 2 GA (CNTF2); and phase 2 late and early stage RP (CNTF3, and CNTF4) studies received an ECT-CNTF implant, designated as "NT-501," in one eye. Per protocol, all implants (n = 10) were removed at 6 months from the CNTF1 study patients. Explant for the phase 2 studies was optional, but several patients were explanted at 12, 18, and 24 months post implant. A small amount of vitreous sample was collected at the time of explant. The rate of CNTF secretion from the explants and the corresponding vitreous CNTF levels were evaluated for each time point. Serum samples from these patients were evaluated for CNTF, anti-CNTF antibodies, and antibodies to the encapsulated cells. RESULTS: NT-501 implants produced CNTF consistently over a 2-year period. The calculated half-life of CNTF in the vitreous continuously delivered by ECT implants was 51 months, with CNTF levels statistically equivalent between the 6- and 24-month implant period. CNTF, anti-CNTF antibodies, and antibodies to the encapsulated cells were not detected in the serum of patients. CONCLUSIONS: This retrospective study demonstrated that the intraocular ECT implant has a favorable pharmacokinetic profile for the treatment of chronic retinal degenerative diseases without systemic exposure. (ClinicalTrials.gov numbers, NCT00063765, NCT00447954, NCT00447980, NCT00447993.).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.12-9970

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 192

Metadata

Authors
Kauper, K., McGovern, C., Sherman, S., Heatherton, P., Rapoza, R., Stabila, P., Dean, B., Lee, A., Borges, S., Bouchard, B., & Tao, W.
Venue
Investigative Opthalmology & Visual Science
Published
2012-11-01
Volume
53
Issue
12
Pages
7484
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2059323909
Cited by
192
References
4
FWCI
5.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Two-Year Intraocular Delivery of Ciliary Neurotrophic Factor by Encapsulated Cell Technology Implants in Patients with Chronic Retinal Degenerative Diseases. https://app.cochat.ai/papers/10.1167/iovs.12-9970
The paper
Kauper, K., McGovern, C., Sherman, S., Heatherton, P., Rapoza, R., Stabila, P., Dean, B., Lee, A., Borges, S., Bouchard, B., & Tao, W. (2012). Two-Year Intraocular Delivery of Ciliary Neurotrophic Factor by Encapsulated Cell Technology Implants in Patients with Chronic Retinal Degenerative Diseases. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.12-9970

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.