Relationship Between Foveal Cone Structure and Clinical Measures of Visual Function in Patients With Inherited Retinal Degenerations
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
PURPOSE: To study the relationship between cone spacing and density and clinical measures of visual function near the fovea. METHODS: High-resolution images of the photoreceptor mosaic were obtained with adaptive optics scanning laser ophthalmoscopy from 26 patients with inherited retinal degenerations. Cone spacing measures were made close to or at the foveal center (mean [SD] eccentricity, 0.02 [0.03] degree; maximum eccentricity, 0.13 degree) and were converted to Z-scores, fraction of cones, and percentage-of-cones-below-average compared with normal values for each location (based on 37 age-similar visually normal eyes). Z-scores and percentage of cones below average were compared with best-corrected visual acuity (VA) and foveal sensitivity. RESULTS: Visual acuity was significantly correlated with cone spacing (Spearman rank correlation ρ = -0.60, P = 0.003) and was preserved (≥ 80 letters), despite cone density measures that were 52% below normal. Foveal sensitivity showed significant correlation with cone spacing (ρ = -0.47, P = 0.017) and remained normal (≥ 35 decibels), despite density measures that were approximately 52% to 62% below normal. CONCLUSIONS: Cone density was reduced by up to 62% below normal at or near the fovea in eyes with VA and sensitivity that remained within normal limits. Despite a significant correlation with foveal cone spacing, VA and sensitivity are insensitive indicators of the integrity of the foveal cone mosaic. Direct, objective measures of cone structure may be more sensitive indicators of disease severity than VA or foveal sensitivity in eyes with inherited retinal degenerations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bootstrap Methods and their Application
Davison, A. C., & Hinkley, D. V. (1997) · doi:10.1017/cbo9780511802843 · Cited by 7,350
Human photoreceptor topography
Curcio, C. A., Sloan, K. R., Kalina, R. E., & Hendrickson, A. E. (1990) · Journal of Comparative Neurology · doi:10.1002/cne.902920402 · Cited by 3,167
Hartong, D. T., Berson, E. L., & Dryja, T. P. (2006) · The Lancet · doi:10.1016/s0140-6736(06)69740-7 · Cited by 2,924
The mosaic of midget ganglion cells in the human retina
Dacey, D. (1993) · The Journal of Neuroscience · doi:10.1523/jneurosci.13-12-05334.1993 · Cited by 480 · cited 1×
“5 arc min,(63) approximately 2200 foveal cones would sample a Goldmann III stimulus, each corresponding to a single receptive field based on the postreceptoral ‘‘private line’’ hypothesis for foveal cones.(84) This oversampling of numerous receptive fields may lead to an underestimation of subtle visual defects in the…”
The relationship between visual resolution and cone spacing in the human fovea
Rossi, E. A., & Roorda, A. (2010) · Nature Neuroscience · doi:10.1038/nn.2465 · Cited by 255
Self-citationRetinal photoreceptor density decreases with age
Panda-Jonas, S., Jonas, J. B., & Jakobczyk-Zmija, M. (1995) · Ophthalmology · doi:10.1016/s0161-6420(95)30784-1 · Cited by 208
Cited by
Non-syndromic retinitis pigmentosa
Verbakel, S. K., van Huet, R. A. C., Boon, C. J. F., den Hollander, A. I., Collin, R. W. J., Klaver, C. C. W., Hoyng, C. B., Roepman, R., & Klevering, B. J. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.03.005 · Cited by 973
Neuroprotective strategies for retinal disease
Pardue, M. T., & Allen, R. S. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.02.002 · Cited by 237
“Several research groups are using this technology to characterize photoreceptor changes during retinal diseases like RP and AMD (Ratnam et al., 2013; Sun et al., 2016; Zayit-Soudry et al., 2013, 2015), as well as erythrocyte aggregates in retinal capillaries in DR (Arichika et al., 2014) and nerve fi ber bundles in gla…”
InfluentialCsaky, K., Ferris, F., Chew, E. Y., Nair, P., Cheetham, J. K., & Duncan, J. L. (2017) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.17-22339 · Cited by 231
“Until approximately 50% of the cones were lost, visual acuity appeared to be relatively normal, decreasing below 20/25 after that threshold.(7) These findings suggest that combining AOSLO with other techniques such as SD-OCT, microperimetry, and visual acuity could increase the sensitivity of each technique for imagin…”
BackgroundSelf-citationEmerging therapies for inherited retinal degeneration
Scholl, H. P. N., Strauss, R. W., Singh, M. S., Dalkara, D., Roska, B., Picaud, S., & Sahel, J.-A. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2838 · Cited by 219
“In a recent study, using adaptive optics scanning laser ophthalmoscopy (AOSLO), good visual acuities (≥80 letters corresponding to 20/25 or better) were still maintained in patients with retinal dystrophies, whereas cone densities in vivo were 52% below normal (100).”
Background
Metadata
- Authors
- Ratnam, K., Carroll, J., Porco, T. C., Duncan, J. L., & Roorda, A.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2013-08-28
- Volume
- 54
- Issue
- 8
- Pages
- 5836
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2140078205
- Cited by
- 109
- References
- 6
- FWCI
- 2.42
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Relationship Between Foveal Cone Structure and Clinical Measures of Visual Function in Patients With Inherited Retinal Degenerations. https://app.cochat.ai/papers/10.1167/iovs.13-12557
- The paper
- Ratnam, K., Carroll, J., Porco, T. C., Duncan, J. L., & Roorda, A. (2013). Relationship Between Foveal Cone Structure and Clinical Measures of Visual Function in Patients With Inherited Retinal Degenerations. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.13-12557
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.