Transcorneal Electrical Stimulation for Patients With Retinitis Pigmentosa: A Prospective, Randomized, Sham-Controlled Follow-up Study Over 1 Year
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Purpose: After promising results of an exploratory study, this study was designed to assess the safety and efficacy of transcorneal electrical stimulation (TES) over 1 year in patients with retinitis pigmentosa (RP). Methods: We included 52 RP patients in this prospective, randomized, partially-masked study which was done in accordance with rules of good clinical practice. Transcorneal electrical stimulation by Okustim was applied monocularly for 30 minutes per week for 52 consecutive weeks. Patients were assigned randomly to the groups: sham, 150%, or 200% of individual electrical phosphene threshold (EPT). Visual acuity (retroilluminated Snellen charts), visual field (VF; Octopus 900), electroretinography (ERG), rod and cone full-field stimulus threshold, EPTs and IOP were assessed. Primary outcome measures were VF area; secondary outcome measures were development of ERG parameters. Results: The application of TES was tolerated well. Dry eye symptoms (31 of 52 patients) were registered as the main adverse event. Throughout the study period, the VF area showed only a trend for prevention of VF loss in the 200% group (P = 0.24). A significant improvement of light-adapted single flash b-wave was noted for the 200% (P < 0.0001) and 150% (P = 0.006) groups compared to the sham group. Tendencies of improved function were observed for scotopic b-wave amplitude for the 200% group (P = 0.097). Other examination methods did not reach statistical significance. Conclusions: The safety and acceptable tolerability of weekly TES self-administered by patients at home was confirmed over the course of 1 year. Objectively measured improvements in retinal function with ERG provide support for the potential benefits of TES for RP patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Major Cell Populations of the Mouse Retina
Jeon, C.-J., Strettoi, E., & Masland, R. H. (1998) · The Journal of Neuroscience · doi:10.1523/jneurosci.18-21-08936.1998 · Cited by 1,429
Electrical stimulation promotes sensory neuron regeneration and growth-associated gene expression
Geremia, N. M., Gordon, T., Brushart, T. M., Al-Majed, A. A., & Verge, V. M. K. (2007) · Experimental Neurology · doi:10.1016/j.expneurol.2007.01.040 · Cited by 430
Cited by
Non-syndromic retinitis pigmentosa
Verbakel, S. K., van Huet, R. A. C., Boon, C. J. F., den Hollander, A. I., Collin, R. W. J., Klaver, C. C. W., Hoyng, C. B., Roepman, R., & Klevering, B. J. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.03.005 · Cited by 973
Neuroprotective strategies for retinal disease
Pardue, M. T., & Allen, R. S. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.02.002 · Cited by 237
“Applying transcorneal electrical stimulation to patients with RP provided an increase of 1.3x in b-wave amplitude and a 1.1x increase in visual fi eld area (Schatz et al., 2017).”
Stingl, K., Schippert, R., Bartz-Schmidt, K. U., Besch, D., Cottriall, C. L., Edwards, T. L., Gekeler, F., Greppmaier, U., Kiel, K., Koitschev, A., et al. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00445 · Cited by 198
“…2008; MacLaren et al., 2014; Bennett et al., 2016), electrostimulation might be an option to delay progress for some retinitis pigmentosa patients (Schatz et al., 2011, 2017) and retinal implants have shown to restore measurable vision in some blind patients sufficient for object localization and…”
BackgroundEdwards, T. L., Cottriall, C. L., Xue, K., Simunovic, M. P., Ramsden, J. D., Zrenner, E., & MacLaren, R. E. (2018) · Ophthalmology · doi:10.1016/j.ophtha.2017.09.019 · Cited by 193
Self-citationRoska, B., & Sahel, J.-A. (2018) · Nature · doi:10.1038/s41586-018-0076-4 · Cited by 161
Metadata
- Authors
- Schatz, A., Pach, J., Gosheva, M., Naycheva, L., Willmann, G., Wilhelm, B., Peters, T., Bartz-Schmidt, K. U., Zrenner, E., Messias, A., & Gekeler, F.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2017-01-18
- Volume
- 58
- Issue
- 1
- Pages
- 257
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2581794159
- Cited by
- 98
- References
- 2
- FWCI
- 3.40
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.