CoChat

Safety and Efficacy Clinical Trials for SYL1001, a Novel Short Interfering RNA for the Treatment of Dry Eye Disease

Open access
Benitez-Del-Castillo, José Manuel, Moreno-Montañés, Javier, Jiménez-Alfaro, Ignacio, Muñoz-Negrete, Francisco José, Turman, Krista, Palumaa, Kadi, Sádaba, Belén, González, María Victoria, Ruz, Verónica, Vargas, Beatriz, Pañeda, Covadonga, Martínez, Tamara, Bleau, Anne-Marie, Jimenez, Ana Isabel · 2016 · Investigative Opthalmology & Visual Science
Cited by 100

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Purpose: To evaluate the efficacy and safety of SYL1001, a short interfering (si) RNA targeting the transient receptor potential cation channel subfamily V member 1 (TRPV1), for the treatment of dry eye disease (DED). Methods: This study combines a phase I and two phase II clinical trials to test different doses of SYL1001 in a total of 156 healthy subjects and patients with DED. After 10 days of treatment, the primary efficacy endpoints were the effect on (1) the scoring in the Visual Analogue Scale (VAS) and Ocular Surface Disease Index (OSDI) questionnaires, and (2) ocular tolerance evaluated by corneal fluorescein staining and conjunctival hyperemia. Secondary endpoints included the assessment of systemic and local tolerance. Results: Topical administration of SYL1001 1.125% once daily produced a significant decrease in VAS scores compared with placebo from day 4 until the end of treatment (change from baseline at day 10: -1.73 ± 0.32 vs. -0.91 ± 0.34; P = 0.013). For all treatments, OSDI scores were significantly reduced compared to their respective baseline values (P < 0.01), although no significant changes were detected between groups. Conjunctival hyperemia (quantified as normal or abnormal) significantly improved after instillation of SYL1001 1.125% compared with placebo (50% vs. 20%; P < 0.05). Excellent tolerability was reported, with no differences in the rates of occurrence of adverse events between groups. Conclusion: These trials achieved their primary endpoints of identifying the most effective dose of SYL1001 (1.125%). SYL1001 showed a large safety margin and may provide novel therapeutic opportunity for the relief of dry eye. (ClinicalTrials.gov numbers, NCT01438281, NCT01776658, and NCT02455999.).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.16-20303

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Benitez-Del-Castillo, J. M., Moreno-Montañés, J., Jiménez-Alfaro, I., Muñoz-Negrete, F. J., Turman, K., Palumaa, K., Sádaba, B., González, M. V., Ruz, V., Vargas, B., Pañeda, C., Martínez, T., Bleau, A.-M., & Jimenez, A. I.
Venue
Investigative Opthalmology & Visual Science
Published
2016-11-22
Volume
57
Issue
14
Pages
6447
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2558759008
Cited by
100
References
2
FWCI
6.35
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.