Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 259

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

The Biomechanical Effect of Corneal Collagen Cross-Linking (CXL) With Riboflavin and UV-A is Oxygen Dependent

Open access
Richoz, Olivier, Hammer, Arthur, Tabibian, David, Gatzioufas, Zisis, Hafezi, Farhad·2013·Translational Vision Science & Technology

Abstract

PURPOSE: In an attempt to reduce treatment time in corneal collagen cross-linking (CXL) with riboflavin and ultraviolet-A (UV-A), recent protocol modifications include shorter irradiation times at higher fluence, while maintaining constant total applied energy (Bunsen-Roscoe law of reciprocity). While such parameter changes might produce similar biological results within a certain range, the limits of reciprocity are unknown. Limitations in the corneal oxygen diffusion capacity and its potential impact on the efficacy of CXL, raise concerns regarding the efficiency of high-fluence CXL, and also of transepithelial CXL. METHODS: = 20 each). Five-millimeter corneal stripes were prepared and biomechanical stiffness was measured using an extensometer. RESULTS: Corneas cross-linked under normal oxygen levels showed a significant increase in biomechanical stability (14.36 MPa ± 2.69 SD), whereas corneas treated similarly, but in a low-oxygen atmosphere showed a Young's modulus similar to untreated controls (11.72 MPa ± 2.77 SD). CONCLUSIONS: The biomechanical effect of CXL seems to be oxygen dependent. This dependency will be of particular importance in high-fluence and transepithelial CXL and will most likely require major protocol modifications to maintain the efficiency of the method. TRANSLATIONAL RELEVANCE: The oxygen dependency of CXL shown here raises concerns about the effectiveness of high-fluence and transepithelial CXL. Both methods were introduced to clinical ophthalmology without thorough validation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/tvst.2.7.6

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Research works printed but not linked: 13

  1. 10.1097/ICO.0b013e3181915943 · doi:10.1097/ico.0b013e3181915943
  2. 10.1016/j.jcrs.2007.07.028 · doi:10.1016/j.jcrs.2007.07.028
  3. 10.1016/j.ajo.2009.10.021 · doi:10.1016/j.ajo.2009.10.021
  4. 10.3928/1081597X-20100331-01 · doi:10.3928/1081597x-20100331-01
  5. 10.1097/ICO.0b013e31822159f6 · doi:10.1097/ico.0b013e31822159f6
  6. 10.3928/1081597X-20121011-01 · doi:10.3928/1081597x-20121011-01
  7. 10.1016/j.ophtha.2011.11.007 · doi:10.1016/j.ophtha.2011.11.007
  8. 10.1016/j.ophtha.2012.12.027 · doi:10.1016/j.ophtha.2012.12.027
  9. 10.3928/1081597X-20090401-02 · doi:10.3928/1081597x-20090401-02
  10. 10.1016/j.jcrs.2008.11.036 · doi:10.1016/j.jcrs.2008.11.036
  11. 10.1016/j.jcrs.2012.01.024 · doi:10.1016/j.jcrs.2012.01.024
  12. 10.1016/j.jcrs.2009.07.008 · doi:10.1016/j.jcrs.2009.07.008
  13. 10.1016/0014-4835(74)90112-2 · doi:10.1016/0014-4835(74)90112-2

Cited by

See all 259

Metadata

Authors
Richoz, O., Hammer, A., Tabibian, D., Gatzioufas, Z., & Hafezi, F.
Venue
Translational Vision Science & Technology
Published
2013-11
Volume
2
Issue
7
Pages
6
ISSN
2164-2591 (ISSN-L)
OpenAlex
W2005469821
Cited by
259
References
7
FWCI
11.88
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Biomechanical Effect of Corneal Collagen Cross-Linking (CXL) With Riboflavin and UV-A is Oxygen Dependent. https://app.cochat.ai/papers/10.1167/tvst.2.7.6
The paper
Richoz, O., Hammer, A., Tabibian, D., Gatzioufas, Z., & Hafezi, F. (2013). The Biomechanical Effect of Corneal Collagen Cross-Linking (CXL) With Riboflavin and UV-A is Oxygen Dependent. Translational Vision Science & Technology. https://doi.org/10.1167/tvst.2.7.6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.