The DOI matches its Crossref record.
Considerations of the physiological variables that determine the blood carboxyhemoglobin concentration in man.
Open accessAbstract
were analyzed for CO concentrations with an infrared CO meter. This instrument has an error (SD) of 4-0.00004% CO and requires a 200-ml sample. These samples were col- lected during the summer of 1964. Smoking is prohibited in the areas where these samples were collected. We also measured the CO concentrations in air samples taken from smoke-filled conference rooms, a small nonventilated room that we purposely filled with smoke by burning cigarettes, and a rural area well away from automobile combustion. Diurnal changes in blood (COHb) were measured in one subject and compared with the changes in percentage of CO in his environment. Blood (COHb) was determined by a method in which gas extracted from a 2-ml blood sample is measured in the infrared CO meter. This method has an error (SD) of 40.03% (COHb)( 10).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biochemical verification of tobacco use and cessation
Benowitz, N. L., III, P. J., Ahijevych, K., Jarvis, M. J., Hall, S., LeHouezec, J., Hansson, A., Lichtenstein, E., Henningfield, J., Tsoh, J., et al. (2002) · Nicotine & Tobacco Research · doi:10.1080/14622200210123581 · Cited by 1,800
2017 ERS/ATS standards for single-breath carbon monoxide uptake in the lung
Graham, B. L., Brusasco, V., Burgos, F., Cooper, B. G., Jensen, R., Kendrick, A., MacIntyre, N. R., Thompson, B. R., & Wanger, J. (2017) · European Respiratory Journal · doi:10.1183/13993003.00016-2016 · Cited by 972
Biochemical verification of tobacco use and abstinence: 2019 update
Benowitz, N. L., Bernert, J. T., Foulds, J., Hecht, S. S., Jacob, P., Jarvis, M. J., Joseph, A., Oncken, C., & Piper, M. E. (2020) · Nicotine & Tobacco Research · doi:10.1093/ntr/ntz132 · Cited by 619
The biological effects of carbon monoxide on the pregnant woman, fetus, and newborn infant
Longo, L. D. (1977) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(77)90824-9 · Cited by 485
Metadata
- Authors
- Coburn, R. F., Forster, R. E., & Kane, P. B.
- Venue
- Journal of Clinical Investigation
- Published
- 1965-11-01
- Volume
- 44
- Issue
- 11
- Pages
- 1899-1910
- ISSN
- 0021-9738 (ISSN-L)
- OpenAlex
- W2140545704
- Cited by
- 433
- References
- 0
- FWCI
- 2.85
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Considerations of the physiological variables that determine the blood carboxyhemoglobin concentration in man. https://app.cochat.ai/papers/10.1172/jci105296
- The paper
- Coburn, R. F., Forster, R. E., & Kane, P. B. (1965). Considerations of the physiological variables that determine the blood carboxyhemoglobin concentration in man. Journal of Clinical Investigation. https://doi.org/10.1172/jci105296
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.