Respiratory Function of the Placenta as Determined with Carbon Monoxide in Sheep and Dogs*
Open accessThe DOI matches its Crossref record.
Abstract
A technique is described for studying the respiratory function of the placenta using carbon monoxide, a gas whose exchange across the placenta between the maternal and fetal circulations is limited by diffusion rather than blood flow. During the steady state before the introduction of CO, the normal concentration of carboxyhemoglobin in the ewe, [COHb](M), is approximately 0.90%, and that in the fetus is 2.9%, the ratio [COHb](F)/[COHb](M) being 3.2. In dogs the corresponding values are 1.9%, 4.8%, and 2.4%. After the introduction of CO into the mother animal, CO diffused across the placenta slowly with an equilibration half-time of approximately 2 hours. The average carbon monoxide diffusing capacity (D(Pco)) of the placenta during maternal to fetal exchange was 0.54 ml per (minute x mm Hg x kg fetal weight) (SD +/- 0.13) in sheep and 0.57 ml per (minute x mm Hg x kg) (SD +/- 0.18) in dogs. The fetal to maternal placental diffusing capacity in two sheep was 0.54 ml per (minute x mm Hg x kg). Calculations considering the relative rates of reaction of O(2) and CO with red cell hemoglobin and the relative rates of diffusion of the two gases suggest that the true D(Po2) should be about 1.2 to 2 times greater than the D(Pco) or 0.65 to 1.1 per (minute x mm Hg x kg). This is about 5 times greater than the reported value of D(Po2) calculated from measurements of P(O2) in the mixed uterine and umbilical venous blood. With a diffusing capacity of this magnitude the maternal and fetal placental end capillary P(O2) would approach equilibrium, becoming too small to measure, and the calculation of D(Po2) would be unreliable. We suggest that the apparent end capillary P(o2) gradients of 15 to 20 mm Hg, obtained from sampling uterine and umbilical venous blood, result from a combination of uneven distribution of maternal and fetal placental blood flow and from placental oxygen consumption.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The biological effects of carbon monoxide on the pregnant woman, fetus, and newborn infant
Longo, L. D. (1977) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(77)90824-9 · Cited by 485
Self-citationLongo, L. D., & Meschia, G. (2000) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/s0301-2115(00)00259-1 · Cited by 379
Self-citationOvine placentome morphology: Effect of high altitude, long-term hypoxia
Penninga, L., & Longo, L. D. (1998) · Placenta · doi:10.1016/s0143-4004(98)90008-x · Cited by 82
Self-citationCurrent topic: Comparative physiology of placental oxygen transport
Wilkening, R. B., & Meschia, G. (1992) · Placenta · doi:10.1016/0143-4004(92)90002-b · Cited by 82
Krebsa, C., Longob, L. D., & Leiser, R. (1997) · Placenta · doi:10.1016/s0143-4004(97)90070-9 · Cited by 71
Metadata
- Authors
- Longo, L. D., Power, G. G., & Forster, R. E.
- Venue
- Journal of Clinical Investigation
- Published
- 1967-05-01
- Volume
- 46
- Issue
- 5
- Pages
- 812-828
- ISSN
- 0021-9738 (ISSN-L)
- OpenAlex
- W2003449933
- Cited by
- 68
- References
- 0
- FWCI
- 19.72
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.