Serum triiodothyronine: measurements in human serum by radioimmunoassay with corroboration by gas-liquid chromatography
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Serum triiodothyronine (T(3)) has been measured by radioimmunoassay and corroborated by analysis of the identical samples with a previously described gas-liquid chromatographic technique. Special features of the radioimmunoassay procedure which permit determinations in unextracted serum include the use of a T(3)-free serum preparation for the construction of the standard curve and of tetrachlorothyronine to inhibit binding of T(3) to thyroxine-binding globulin.T(3) values by radioimmunoassay were 138 +/-23 ng/100 ml (mean +/-SD) in 82 normal subjects, 62 +/-9 ng/100 ml in 45 hypothyroid patients, and 494 +/-265 ng/100 ml in 60 patients with toxic diffuse goiter. In the hypothyroid group, the range was similar in patients with both primary and secondary hypothyroidism. There was no overlap between the three thyroidal states. Elevated T(3) levels were seen in 40 cases that appeared clinically hyperthyroid but had normal serum thyroxine (T(3)) determinations, a syndrome we have called T(3) toxicosis. Values obtained with radioimmunoassay agreed closely with those we had previously found by gas-liquid chromatography which were 68 +/-2 ng/100 ml in hypothyroidism, 137 +/-23 ng/100 ml in normal subjects, and 510 +/-131 ng/100 ml in untreated toxic diffuse goiter. Since T(3) is very potent and its level varies in different clinical states, accurate T(3) measurements are required to assess a patient's thyroid status properly. The radioimmunoassay for T(3) appears to be sufficiently sensitive, precise, and simple to permit its routine clinical application for this purpose.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Conversion of Thyroxine (T4) to triiodothyronine (T3) in athyreotic human subjects
Braverman, L. E., Ingbar, S. H., & Sterling, K. (1970) · Journal of Clinical Investigation · doi:10.1172/jci106304 · Cited by 485
Triiodothyronine Radioimmunoassay
Lieblich, J., & Utiger, R. D. (1972) · Journal of Clinical Investigation · doi:10.1172/jci106786 · Cited by 128
The Radioimmunoassay of Serum Triiodothyronine
Ekins, R. P., Brown, B. L., Ellis, S. M., & Reith, W. S. (1970) · Clinical Science · doi:10.1042/cs038027pb · Cited by 11
Cited by
Samuels, H. H., & Tsai, J. S. (1973) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.70.12.3488 · Cited by 339
Surks, M. I., Schadlow, A. R., Stock, J. M., & Oppenheimer, J. H. (1973) · Journal of Clinical Investigation · doi:10.1172/jci107244 · Cited by 223
“some published methods in which the binding of T3 to plasma proteins in the assay mixture is blocked by addition of other agents (2-5) but somewhat greater than that of other reports in which the mean plasma T3 of euthyroid individuals is in the range of 100-110 ng/100 ml (4, 5).”
MethodSurks, M. I., Schadlow, A. R., & Oppenheimer, J. H. (1972) · Journal of Clinical Investigation · doi:10.1172/jci107137 · Cited by 188
Hollander, C., Mitsuma, T., Nihei, N., Shenkman, L., Zane Burday, S., & Blum, M. (1972) · The Lancet · doi:10.1016/s0140-6736(72)90408-4 · Cited by 61
Self-citationThyroid function tests and their alterations by drugs
Chopra, I. J., & Solomon, D. H. (1976) · Pharmacology & Therapeutics. Part C: Clinical Pharmacology and Therapeutics · doi:10.1016/s0362-5486(76)80026-x
Metadata
- Authors
- Mitsuma, T., Nihei, N., Gershengorn, M. C., & Hollander, C. S.
- Venue
- Journal of Clinical Investigation
- Published
- 1971-12-01
- Volume
- 50
- Issue
- 12
- Pages
- 2679-2688
- ISSN
- 0021-9738 (ISSN-L)
- OpenAlex
- W2108002609
- Cited by
- 105
- References
- 3
- FWCI
- 29.10
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.