Plasma mevalonate as a measure of cholesterol synthesis in man.
Open accessAbstract
Measurement of mevalonic acid (MVA) concentrations in plasma or 24-h urine samples is shown to be useful in studies of the regulation of 3-hydroxy-3-methylglutaryl coenzyme A (HMG-CoA) reductase and cholesterol synthesis. Plasma MVA concentrations, measured either at 7-9 a.m. after an overnight fast, or throughout the 24-h cycle, were compared with cholesterol synthesis rates that were measured by the sterol balance method: plasma MVA concentrations were directly related to the rate of whole body cholesterol synthesis (r = 0.972; p less than 0.001; n = 18) over a tenfold range of cholesterol synthesis rates. Moreover, hourly examination of MVA concentrations throughout the day demonstrated that interventions such as fasting or cholesterol feeding cause suppression of the postmidnight diurnal rise in plasma MVA concentrations, with little change in the base-line of the rhythm. Thus, the daily rise and fall of plasma MVA appears to reflect changes in tissues and organs, such as the liver and intestine, that are known to be most sensitive to regulation by fasting or by dietary cholesterol. The hypothesis that short-term regulation of HMG-CoA reductase in tissues is quickly reflected by corresponding variations in plasma MVA was tested by using a specific inhibitor of HMG-CoA reductase, mevinolin, to block MVA synthesis. Mevinolin caused a dose-dependent lowering of plasma MVA after a single dose; and in patients who received the drug twice a day for 4 wk, it decreased 24-h urinary MVA output. Significant lowering of plasma cholesterol was achieved through administration of mevinolin at doses that only moderately limit MVA production.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The discovery and development of HMG-CoA reductase inhibitors.
Endo, A. (1992) · Journal of Lipid Research · doi:10.1016/s0022-2275(20)41379-3 · Cited by 847
HMG-CoA Reductase Inhibitors for Treatment of Hypercholesterolemia
Oates, J. A., Wood, A. J. J., & Grundy, S. M. (1988) · New England Journal of Medicine · doi:10.1056/nejm198807073190105 · Cited by 758
Clinical Pharmacokinetics of Atorvastatin
Lennern??s, H. (2003) · Clinical Pharmacokinetics · doi:10.2165/00003088-200342130-00005 · Cited by 623
Lea, A. P., & McTavish, D. (1997) · Drugs · doi:10.2165/00003495-199753050-00011 · Cited by 290
Pharmacology of competitive inhibitors of HMg-CoA reductase
Corsini, A. (1995) · Pharmacological Research · doi:10.1016/1043-6618(95)80042-5 · Cited by 277
Metadata
- Authors
- Parker, T. S., McNamara, D. J., Brown, C. D., Kolb, R., Ahrens, E. H., Alberts, A. W., Tobert, J., Chen, J., & De Schepper, P. J.
- Venue
- Journal of Clinical Investigation
- Published
- 1984-09-01
- Volume
- 74
- Issue
- 3
- Pages
- 795-804
- ISSN
- 0021-9738 (ISSN-L)
- OpenAlex
- W2100680747
- Cited by
- 167
- References
- 0
- FWCI
- 7.22
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Plasma mevalonate as a measure of cholesterol synthesis in man. https://app.cochat.ai/papers/10.1172/jci111495
- The paper
- Parker, T. S., McNamara, D. J., Brown, C. D., Kolb, R., Ahrens, E. H., Alberts, A. W., Tobert, J., Chen, J., & De Schepper, P. J. (1984). Plasma mevalonate as a measure of cholesterol synthesis in man. Journal of Clinical Investigation. https://doi.org/10.1172/jci111495
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.