Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 210

The DOI matches its Crossref record.

Use of a murine monoclonal antibody for detection of circulating plasma DF3 antigen levels in breast cancer patients.

Open access
Hayes, D F, Sekine, H, Ohno, T, Abe, M, Keefe, K, Kufe, D W·1985·Journal of Clinical Investigation

Abstract

The murine monoclonal antibody (MAb), designated DF3, reacts with a 300,000-mol wt mammary epithelial antigen. A sequential double-determinant radioimmunoassay (RIA) has been developed to monitor circulating DF3 antigen. Using this assay, we have demonstrated that 33 of 36 normal women had plasma RIA antigen levels less than 150 U/ml. In contrast, 33 of 43 patients (76%) with metastatic breast cancer had RIA DF3 antigen levels greater than or equal to 150 U/ml. The difference between these two groups was statistically significant (P less than 0.001). Similar results have been obtained with a double-determinant enzyme-linked immunoassay (EIA). Only 6 of 111 age-matched normal subjects had EIA DF3 antigens levels greater than or equal to 30 U/ml, while 42 of 58 patients (72%) with breast cancer had levels equal to or above this value. Thus, similar patterns of specificity are obtained with the EIA or RIA. The elevation of circulating DF3 antigen levels in breast cancer patients has been confirmed by transfer blot assays. MAb DF3 reactivity occurred predominantly with circulating antigens of three different molecular weights ranging from 300,000 to approximately 400,000 mol wt. We also demonstrate that patients with both primary and metastatic breast cancer who were free of detectable disease at the time of sampling have DF3 antigen levels that are similar to those obtained from normal subjects. While patients with hepatoma (27%) and ovarian carcinoma (47%) also had elevated circulating DF3 antigen levels, the results suggest that DF3 antigen levels may be useful in distinguishing breast cancer patients from those with esophageal, gastric, colorectal, pancreatic, and lung carcinomas. Furthermore, the results of the RIA, EIA, and transblot analyses demonstrate that the measurement of circulating DF3 antigen levels provides a new and potentially useful marker to follow the clinical course of patients with metastatic breast cancer.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1172/jci111875

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 210

Metadata

Authors
Hayes, D. F., Sekine, H., Ohno, T., Abe, M., Keefe, K., & Kufe, D. W.
Venue
Journal of Clinical Investigation
Published
1985-05-01
Volume
75
Issue
5
Pages
1671-1678
ISSN
0021-9738 (ISSN-L)
OpenAlex
W1983380116
Cited by
210
References
0
FWCI
10.45
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Use of a murine monoclonal antibody for detection of circulating plasma DF3 antigen levels in breast cancer patients. https://app.cochat.ai/papers/10.1172/jci111875
The paper
Hayes, D. F., Sekine, H., Ohno, T., Abe, M., Keefe, K., & Kufe, D. W. (1985). Use of a murine monoclonal antibody for detection of circulating plasma DF3 antigen levels in breast cancer patients. Journal of Clinical Investigation. https://doi.org/10.1172/jci111875

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.