The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Electrical and mechanical activity in the human lower esophageal sphincter during diaphragmatic contraction.
Open accessAbstract
To determine the effect of contraction of the diaphragm on the lower esophageal sphincter (LES) pressure, we studied eight healthy volunteers during spontaneous breathing, maximal inspiration, and graded inspiratory efforts against a closed airway (Muller's maneuver). Electrical activity of the crural diaphragm (DEMG) was recorded from bipolar esophageal electrodes, transdiaphragmatic pressure (Pdi) was calculated as the difference between gastric and esophageal pressures, and LES pressure was recorded using a sleeve device. During spontaneous breathing, phasic inspiratory DEMG was accompanied by phasic increases in Pdi and LES pressure. With maximal inspiration, DEMG increased 15-20-fold compared with spontaneous inspiration, and LES pressure rose from an end-expiratory pressure of 21 to 90 mmHg. Similar values were obtained during maximal Muller's maneuvers. LES pressure fell promptly when the diaphragm relaxed. Graded Muller's maneuver resulted in proportional increases in the Pdi, LES pressure, and DEMG. The LES pressure was always greater than Pdi and correlated with it in a linear fashion (P less than 0.001). We conclude that the contraction of the diaphragm exerts a sphincteric action at the LES, and that this effect is an important component of the antireflux barrier.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Draper, M. H., Ladefoged, P., & Whitteridge, D. (1959) · Journal of Speech and Hearing Research · doi:10.1044/jshr.0201.16 · Cited by 144
Cited by
Mittal, R. K., & Balaban, D. H. (1997) · New England Journal of Medicine · doi:10.1056/nejm199703273361306 · Cited by 644
Self-citationPathophysiology of Gastroesophageal Reflux Disease
Tack, J., & Pandolfino, J. E. (2018) · Gastroenterology · doi:10.1053/j.gastro.2017.09.047 · Cited by 417
AGA technical review on the clinical use of esophageal manometry
Pandolfino, J. E., & Kahrilas, P. J. (2005) · Gastroenterology · doi:10.1053/j.gastro.2004.11.008 · Cited by 324
The effect of hiatus hernia on gastro-oesophageal junction pressure
Kahrilas, P. J., Lin, S., Chen, J., & Manka, M. (1999) · Gut · doi:10.1136/gut.44.4.476 · Cited by 312
Physiology of Normal Esophageal Motility
Goyal, R. K., & Chaudhury, A. (2008) · Journal of Clinical Gastroenterology · doi:10.1097/mcg.0b013e31816b444d · Cited by 294
Metadata
- Authors
- Mittal, R. K., Rochester, D. F., & McCallum, R. W.
- Venue
- Journal of Clinical Investigation
- Published
- 1988-04-01
- Volume
- 81
- Issue
- 4
- Pages
- 1182-1189
- ISSN
- 0021-9738 (ISSN-L)
- OpenAlex
- W1976441120
- Cited by
- 192
- References
- 1
- FWCI
- 5.38
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.