Duodenal iron proteins in idiopathic hemochromatosis.
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This study was undertaken to assess the relationship between iron absorption and the concentration of duodenal iron proteins in normal subjects and patients with idiopathic hemochromatosis (IH). Biopsies were obtained endoscopically from the duodenum in 17 normal subjects, 3 of whom were mildly iron deficient, and 7 patients with untreated IH. The absorption of both heme and nonheme iron was increased in IH despite a 20-fold elevation in serum ferritin. Immunoassays using MAb were used to measure transferrin, H-rich ferritin, and L-rich ferritin in mucosal samples. Mucosal transferrin concentrations in normal subjects did not correlate with either iron status or iron absorption, indicating that mucosal transferrin plays no physiological role in iron absorption. Mucosal transferrin was significantly lower in IH, presumably because of a decrease in mucosal transferrin receptors. Mucosal H and L ferritin concentrations were directly related to body iron stores and inversely related to iron absorption in normal subjects. In IH, mucosal H and L ferritin failed to increase in parallel with the serum ferritin, but were appropriate for the level of iron absorption. The relationship of mucosal H/L ferritin in IH did not differ from that observed in normal subjects. Our findings indicate that the major abnormality in duodenal iron proteins in IH is a parallel decrease in the concentration of H- and L-rich ferritin. It is not evident whether this is the result or the cause of the absorptive abnormality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Food Iron Absorption Measured by an Extrinsic Tag
Cook, J. D., Layrisse, M., Martinez-Torres, C., Walker, R., Monsen, E., & Finch, C. A. (1972) · Journal of Clinical Investigation · doi:10.1172/jci106875 · Cited by 320
Self-citation
Cited by
Iron Metabolism: A Comprehensive Review
Beard, J. L., Dawson, H., & Piñero, D. J. (2009) · Nutrition Reviews · doi:10.1111/j.1753-4887.1996.tb03794.x · Cited by 322
Contributions of heme and nonheme iron to human nutrition
Carpenter, C. E., & Mahoney, A. W. (1992) · Critical Reviews in Food Science and Nutrition · doi:10.1080/10408399209527576 · Cited by 318
Assessment of the role of nonheme-iron availability in iron balance
Cook, J., Dassenko, S., & Lynch, Sr. (1991) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/54.4.717 · Cited by 265
Self-citationCook, J. (1990) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/51.2.301 · Cited by 217
“intestinal concentration of both L- and H-type ferntin in healthy subjects ( 40 ).”
BackgroundSelf-citationSantos, M., Schilham, M. W., Rademakers, L. H., Marx, J. J., de Sousa, M., & Clevers, H. (1996) · The Journal of experimental medicine · doi:10.1084/jem.184.5.1975 · Cited by 195
“testinal mucosal cells in regulating iron absorption (63-68).”
Metadata
- Authors
- Whittaker, P., Skikne, B. S., Covell, A. M., Flowers, C., Cooke, A., Lynch, S. R., & Cook, J. D.
- Venue
- Journal of Clinical Investigation
- Published
- 1989-01-01
- Volume
- 83
- Issue
- 1
- Pages
- 261-267
- ISSN
- 0021-9738 (ISSN-L)
- OpenAlex
- W2011442905
- Cited by
- 91
- References
- 1
- FWCI
- 5.49
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Duodenal iron proteins in idiopathic hemochromatosis. https://app.cochat.ai/papers/10.1172/jci113868
- The paper
- Whittaker, P., Skikne, B. S., Covell, A. M., Flowers, C., Cooke, A., Lynch, S. R., & Cook, J. D. (1989). Duodenal iron proteins in idiopathic hemochromatosis. Journal of Clinical Investigation. https://doi.org/10.1172/jci113868
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.