Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 236

The DOI matches its Crossref record.

The inverse association of plasma lipoprotein(a) concentrations with apolipoprotein(a) isoform size is not due to differences in Lp(a) catabolism but to differences in production rate.

Open access
Rader, D J, Cain, W, Ikewaki, K, Talley, G, Zech, L A, Usher, D, Brewer, H B · 1994 · Journal of Clinical Investigation

Abstract

Lipoprotein(a) (Lp[a]) is an atherogenic lipoprotein which is similar in structure to low density lipoproteins (LDL) but contains an additional protein called apolipoprotein(a) (apo[a]). Apo(a) is highly polymorphic in size, and there is a strong inverse association between the size of the apo(a) isoform and the plasma concentration of Lp(a). We directly compared the in vivo catabolism of Lp(a) particles containing different size apo(a) isoforms to establish whether there is an effect of apo(a) isoform size on the catabolic rate of Lp(a). In the first series of studies, four normal subjects were injected with radio-labeled S1-Lp(a) and S2-Lp(a) and another four subjects were injected with radiolabeled S2-Lp(a) and S4-Lp(a). No significant differences in fractional catabolic rate were found between Lp(a) particles containing different apo(a) isoforms. To confirm that apo(a) isoform size does not influence the rate of Lp(a) catabolism, three subjects heterozygous for apo(a) were selected for preparative isolation of both Lp(a) particles. The first was a B/S3-apo(a) subject, the second a S4/S6-apo(a) subject, and the third an F/S3-apo(a) subject. From each subject, both Lp(a) particles were preparatively isolated, radiolabeled, and injected into donor subjects and normal volunteers. In all cases, the catabolic rates of the two forms of Lp(a) were not significantly different. In contrast, the allele-specific apo(a) production rates were more than twice as great for the smaller apo(a) isoforms than for the larger apo(a) isoforms. In a total of 17 studies directly comparing Lp(a) particles of different apo(a) isoform size, the mean fractional catabolic rate of the Lp(a) with smaller size apo(a) was 0.329 +/- 0.090 day-1 and of the Lp(a) with the larger size apo(a) 0.306 +/- 0.079 day-1, not significantly different. In summary, the inverse association of plasma Lp(a) concentrations with apo(a) isoform size is not due to differences in the catabolic rates of Lp(a) but rather to differences in Lp(a) production rates.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1172/jci117292

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 236

Metadata

Authors
Rader, D. J., Cain, W., Ikewaki, K., Talley, G., Zech, L. A., Usher, D., & Brewer, H. B.
Venue
Journal of Clinical Investigation
Published
1994-06-01
Volume
93
Issue
6
Pages
2758-2763
ISSN
0021-9738 (ISSN-L)
OpenAlex
W1975168532
Cited by
236
References
0
FWCI
11.94
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The inverse association of plasma lipoprotein(a) concentrations with apolipoprotein(a) isoform size is not due to differences in Lp(a) catabolism but to differences in production rate. https://app.cochat.ai/papers/10.1172/jci117292
The paper
Rader, D. J., Cain, W., Ikewaki, K., Talley, G., Zech, L. A., Usher, D., & Brewer, H. B. (1994). The inverse association of plasma lipoprotein(a) concentrations with apolipoprotein(a) isoform size is not due to differences in Lp(a) catabolism but to differences in production rate. Journal of Clinical Investigation. https://doi.org/10.1172/jci117292

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.