In situ microdialysis in bone tissue. Stimulation of prostaglandin E2 release by weight-bearing mechanical loading.
Open accessThe DOI matches its Crossref record.
Abstract
In this study we describe, to our knowledge, the first experiment using the microdialysis technique for studying the release of prostaglandin E 2 (PGE 2 ) in the proximal tibia metaphysis secondary to mechanical loading.Nine healthy females, six in the loading group and three controls, mean age 34 Ϯ 2 (years Ϯ SEM), participated.A standard microdialysis catheter was inserted into the tibia metaphyseal bone under local anesthesia.Samplings were done every 15 min under a 2-h equilibration period.Thereafter, heel-drops (one impact per second) with as hard impact of the heels into the floor as possible, were done for 5 min by the subjects in the loading group.The control group performed no exercise.Sampling continued after this for another 2-h period.Basal levels of PGE 2 in the proximal tibial metaphysis were determined to a mean of 45 Ϯ 10 pg/ml (mean Ϯ SEM, n ϭ 6).The major finding was a 2.5-3.5-foldincrease in the release of PGE 2 after mechanical loading.The increase was statistically significant ( P Ͻ 0.05 compared with basal levels) 1 h after the mechanical loading and persisted for the rest of the experimental period.No major alterations were observed in the control group.In conclusion, our data demonstrate that in situ microdialysis is a useful method for studying the PGE 2 production in human bone.Furthermore, a rapid and significant increase in PGE 2 levels was noticed in response to dynamic mechanical loading.( J. Clin.Invest.1996.98:2446-2449.)Key words: physical exercise • mechanical loading • bone metabolism • microdialysis • prostaglandins MethodsNine healthy females, six in the mechanical loading group and three in the control group, mean age 34 Ϯ 2 (years Ϯ SEM), with regular menses and on no medication, participated.They were recruited after advertising at the local hospital.The study protocol was approved by the Ethical Committee of the Medical Faculty, University of Umeå
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Primary cilia mediate mechanosensing in bone cells by a calcium-independent mechanism
Malone, A. M. D., Anderson, C. T., Tummala, P., Kwon, R. Y., Johnston, T. R., Stearns, T., & Jacobs, C. R. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0700636104 · Cited by 477
Mechanical Signaling for Bone Modeling and Remodeling
Robling, A. G., & Turner, C. H. (2009) · Critical Reviews™ in Eukaryotic Gene Expression · doi:10.1615/critreveukargeneexpr.v19.i4.50 · Cited by 422
Mechanical regulation of signaling pathways in bone
Thompson, W. R., Rubin, C. T., & Rubin, J. (2012) · Gene · doi:10.1016/j.gene.2012.04.076 · Cited by 409
Langberg, H., Skovgaard, D., Petersen, L. J., Bülow, J., & Kjær, M. (1999) · The Journal of Physiology · doi:10.1111/j.1469-7793.1999.00299.x · Cited by 350
Overview of Brain Microdialysis
Chefer, V. I., Thompson, A. C., Zapata, A., & Shippenberg, T. S. (2009) · Current Protocols in Neuroscience · doi:10.1002/0471142301.ns0701s47 · Cited by 330
Metadata
- Authors
- Thorsen, K., Kristoffersson, A. O., Lerner, U. H., & Lorentzon, R. P.
- Venue
- Journal of Clinical Investigation
- Published
- 1996-12-01
- Volume
- 98
- Issue
- 11
- Pages
- 2446-2449
- ISSN
- 0021-9738 (ISSN-L)
- OpenAlex
- W2061958755
- Cited by
- 95
- References
- 0
- FWCI
- 1.80
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In situ microdialysis in bone tissue. Stimulation of prostaglandin E2 release by weight-bearing mechanical loading. https://app.cochat.ai/papers/10.1172/jci119061
- The paper
- Thorsen, K., Kristoffersson, A. O., Lerner, U. H., & Lorentzon, R. P. (1996). In situ microdialysis in bone tissue. Stimulation of prostaglandin E2 release by weight-bearing mechanical loading. Journal of Clinical Investigation. https://doi.org/10.1172/jci119061
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.