Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 173

The DOI matches its Crossref record.

The effect of intravenous administration of a chimeric anti-IgE antibody on serum IgE levels in atopic subjects: efficacy, safety, and pharmacokinetics.

Open access
Corne, J, Djukanovic, R, Thomas, L, Warner, J, Botta, L, Grandordy, B, Gygax, D, Heusser, C, Patalano, F, Richardson, W, Kilchherr, E, Staehelin, T, Davis, F, Gordon, W, Sun, L, Liou, R, Wang, G, Chang, T W, Holgate, S · 1997 · Journal of Clinical Investigation

Abstract

CGP 51901 is a non-anaphylactogenic mouse/human chimeric anti-human IgE antibody that binds to free IgE and surface IgE of IgE-expressing B cells but not to IgE bound to high affinity IgE receptors (Fc epsilonR1) on mast cells and basophils or low affinity IgE receptors (Fc epsilonR2) on other cells. A phase 1 double-blind, placebo-controlled, single dose study with doses of 3, 10, 30, and 100 mg of CGP 51901 was conducted in 33 pollen-sensitive subjects who had raised levels of serum IgE and received either intravenous CGP 51901 or placebo. The administration of CGP 51901 was well tolerated and resulted in a decrease of serum free IgE levels in a dose-dependent manner, with suppression after 100 mg of CGP 51901 reaching > 96%. Time of recovery to 50% of baseline IgE correlated with the dose of administered antibody and ranged from a mean of 1.3 d for the 3 mg to 39 d for the 100 mg dose. Total IgE, comprised of free and complexed IgE, increased as stored and newly synthesized IgE bound to CGP 51901. Complexed IgE was eliminated at a rate comparable with the terminal half-life of free CGP 51901 (11-13 d at all doses). Only one subject showed a weak antibody response against CGP 51901. We conclude that the use of anti-human IgE antibody is safe and effective in reducing serum IgE levels in atopic individuals and provides a potential therapeutic approach to the treatment of atopic diseases.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1172/jci119252

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 173

Metadata

Authors
Corne, J., Djukanovic, R., Thomas, L., Warner, J., Botta, L., Grandordy, B., Gygax, D., Heusser, C., Patalano, F., Richardson, W., Kilchherr, E., Staehelin, T., Davis, F., Gordon, W., Sun, L., Liou, R., Wang, G., Chang, T. W., & Holgate, S.
Venue
Journal of Clinical Investigation
Published
1997-03-01
Volume
99
Issue
5
Pages
879-887
ISSN
0021-9738 (ISSN-L)
OpenAlex
W2024931925
Cited by
173
References
0
FWCI
6.92
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The effect of intravenous administration of a chimeric anti-IgE antibody on serum IgE levels in atopic subjects: efficacy, safety, and pharmacokinetics. https://app.cochat.ai/papers/10.1172/jci119252
The paper
Corne, J., Djukanovic, R., Thomas, L., Warner, J., Botta, L., Grandordy, B., Gygax, D., Heusser, C., Patalano, F., Richardson, W., Kilchherr, E., Staehelin, T., Davis, F., Gordon, W., Sun, L., Liou, R., Wang, G., Chang, T. W., & Holgate, S. (1997). The effect of intravenous administration of a chimeric anti-IgE antibody on serum IgE levels in atopic subjects: efficacy, safety, and pharmacokinetics. Journal of Clinical Investigation. https://doi.org/10.1172/jci119252

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.