The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Simulated Electrification of a Small Thunderstorm with Two-Moment Bulk Microphysics
Open accessAbstract
Electrification and lightning are simulated for a small continental multicell storm. The results are consistent with observations and thus provide additional understanding of the charging processes and evolution of this storm. The first six observed lightning flashes were all negative cloud-to-ground (CG) flashes, after which intracloud (IC) flashes also occurred between middle and upper levels of the storm. The model simulation reproduces the basic evolution of lightning from low and middle levels to upper levels. The observed lightning indicated an initial charge structure of at least an inverted dipole (negative charge above positive). The simulations show that noninductive charge separation higher in the storm can enhance the main negative charge sufficiently to produce negative CG flashes before upper-level IC flashes commence. The result is a “bottom-heavy” tripole charge structure with midlevel negative charge and a lower positive charge region that is more significant than the upper positive region, in contrast to the traditional tripole structure that has a less significant lower positive charge region. Additionally, the occurrence of cloud-to-ground lightning is not necessarily a result of excess net charge carried by the storm, but it is primarily caused by the local potential imbalance between the lowest charge regions. The two-moment microphysics scheme used for this study predicted mass mixing ratio and number concentration of cloud droplets, rain, ice crystals, snow, and graupel. Bulk particle density of graupel was also predicted, which allows a single category to represent a greater range of particle characteristics. (An additional hail category is available but was not needed for the present study.) The prediction of hydrometeor number concentration is particularly critical for charge separation at higher temperatures (−5° < T < −20°C) in the mixed phase region, where ice crystals are produced by rime fracturing (Hallett–Mossop process) and by splintering of freezing drops. Cloud droplet concentration prediction also affected the rates of inductive charge separation between graupel and droplets.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Efficient Implementation of Weighted ENO Schemes
Jiang, G.-S., & Shu, C.-W. (1996) · Journal of Computational Physics · doi:10.1006/jcph.1996.0130 · Cited by 6,571
Stratocumulus-capped mixed layers derived from a three-dimensional model
Deardorff, J. W. (1980) · Boundary-Layer Meteorology · doi:10.1007/bf00119502 · Cited by 2,046
THE TERMINAL VELOCITY OF FALL FOR WATER DROPLETS IN STAGNANT AIR
Gunn, R., & Kinzer, G. D. (1949) · Journal of Meteorology · doi:10.1175/1520-0469(1949)006<0243:ttvoff>2.0.co;2 · Cited by 1,597
The Simulation of Three-Dimensional Convective Storm Dynamics
Klemp, J. B., & Wilhelmson, R. B. (1978) · Journal of the Atmospheric Sciences · doi:10.1175/1520-0469(1978)035<1070:tsotdc>2.0.co;2 · Cited by 1,417
Production of secondary ice particles during the riming process
HALLETT, J., & MOSSOP, S. C. (1974) · Nature · doi:10.1038/249026a0 · Cited by 1,107
The ULTIMATE conservative difference scheme applied to unsteady one-dimensional advection
Leonard, B. P. (1991) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(91)90232-u · Cited by 1,028
Explicit forecasting of supercooled liquid water in winter storms using the MM5 mesoscale model
Reisner, J., Rasmussen, R. M., & Bruintjes, R. T. (1998) · Quarterly Journal of the Royal Meteorological Society · doi:10.1002/qj.49712454804 · Cited by 996
Time-Splitting Methods for Elastic Models Using Forward Time Schemes
Wicker, L. J., & Skamarock, W. C. (2002) · Monthly Weather Review · doi:10.1175/1520-0493(2002)130<2088:tsmfem>2.0.co;2 · Cited by 954
New Primary Ice-Nucleation Parameterizations in an Explicit Cloud Model
Meyers, M. P., DeMott, P. J., & Cotton, W. R. (1992) · Journal of Applied Meteorology · doi:10.1175/1520-0450(1992)031<0708:npinpi>2.0.co;2 · Cited by 906
Milbrandt, J. A., & Yau, M. K. (2005) · Journal of the Atmospheric Sciences · doi:10.1175/jas3534.1 · Cited by 740
A two-moment cloud microphysics parameterization for mixed-phase clouds. Part 1: Model description
Seifert, A., & Beheng, K. D. (2006) · Meteorology and Atmospheric Physics · doi:10.1007/s00703-005-0112-4 · Cited by 682
Twomey, S. (1959) · Geofisica pura e applicata · doi:10.1007/bf01993560 · Cited by 663
A Double-Moment Multiple-Phase Four-Class Bulk Ice Scheme. Part I: Description
Schoenberg Ferrier, B. (1994) · Journal of the Atmospheric Sciences · doi:10.1175/1520-0469(1994)051<0249:admmpf>2.0.co;2 · Cited by 501
Shu, C.-W. (2003) · International Journal of Computational Fluid Dynamics · doi:10.1080/1061856031000104851 · Cited by 469
The effect of liquid water on thunderstorm charging
Saunders, C. P. R., Keith, W. D., & Mitzeva, R. (1991) · Journal of Geophysical Research Atmospheres · doi:10.1029/91jd00970 · Cited by 425
Bigg, E. K. (1953) · Proceedings of the Physical Society. Section B · doi:10.1088/0370-1301/66/8/309 · Cited by 417
Cotton, W. R., Tripoli, G. J., Rauber, R. M., & Mulvihill, E. A. (1986) · Journal of Climate and Applied Meteorology · doi:10.1175/1520-0450(1986)025<1658:nsoteo>2.0.co;2 · Cited by 400
Wicker, L. J., & Wilhelmson, R. B. (1995) · Journal of the Atmospheric Sciences · doi:10.1175/1520-0469(1995)052<2675:saaotd>2.0.co;2 · Cited by 292
Murakami, M. (1990) · Journal of the Meteorological Society of Japan. Ser. II · doi:10.2151/jmsj1965.68.2_107 · Cited by 287
Simulations of Right- and Left-Moving Storms Produced Through Storm Splitting
Klemp, J. B., & Wilhelmson, R. B. (1978) · Journal of the Atmospheric Sciences · doi:10.1175/1520-0469(1978)035<1097:soralm>2.0.co;2 · Cited by 248
Ziegler, C. L. (1985) · Journal of the Atmospheric Sciences · doi:10.1175/1520-0469(1985)042<1487:rotamv>2.0.co;2 · Cited by 226
Self-citationThe Electrical Structure of Thunderstorms
Workman, E. J., Helzer, R. E., & Pelsor, G. T. (1942) · Cited by 184
An Analysis of Cloud Drop Growth by Collection Part II. Single Initial Distributions
Berry, E. X., & Reinhardt, R. L. (1974) · Journal of the Atmospheric Sciences · doi:10.1175/1520-0469(1974)031<1825:aaocdg>2.0.co;2 · Cited by 175
The effect on thunderstorm charging of the rate of rime accretion by graupel
Brooks, I. M., Saunders, C. P. R., Mitzeva, R., & Peck, S. L. (1997) · Atmospheric Research · doi:10.1016/s0169-8095(96)00043-9 · Cited by 112
Riousset, J. A., Pasko, V. P., Krehbiel, P. R., Thomas, R. J., & Rison, W. (2007) · Journal of Geophysical Research Atmospheres · doi:10.1029/2006jd007621 · Cited by 102
Cited by
Morrison, H., & Milbrandt, J. A. (2015) · Journal of the Atmospheric Sciences · doi:10.1175/jas-d-14-0065.1 · Cited by 664
Li, H., Huang, Y., Hu, S., Wu, N., Liu, X., & Xiao, H. (2021) · Journal of Geophysical Research: Atmospheres · doi:10.1029/2021jd035556 · Cited by 23
Metadata
- Authors
- Mansell, E. R., Ziegler, C. L., & Bruning, E. C.
- Venue
- Journal of the Atmospheric Sciences
- Publisher
- American Meteorological Society
- Published
- 2010-01-01
- Volume
- 67
- Issue
- 1
- Pages
- 171-194
- ISSN
- 0022-4928 (ISSN-L)
- 1520-0469
- OpenAlex
- W2133060702
- Cited by
- 564
- References
- 25
- FWCI
- 3.08
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.