CoChat

ECT Stimulus Intensity: Are Present ECT Devices Too Limited?

Krystal, Andrew D., Dean, Margaret D., Weiner, Richard D., Tramontozzi, Louis A., Connor, Kathryn M., Lindahl, Virginia H., Massie, Ryan W. · 2000 · American Journal of Psychiatry
Cited by 54

The DOI matches its Crossref record.

Abstract

OBJECTIVE: The maximum output charge for ECT devices is limited to 576 millicoulombs in the United States, although there are no data ensuring that this limit will allow consistently effective treatments. The authors examined whether this limit has a negative impact on therapeutic response and, therefore, whether a higher stimulus charge should be available. METHOD: They retrospectively reviewed the records of 471 patients who received a clinical index course of ECT at Duke University between 1991 and 1998. These patients received conservative stimulus dosing of 2.25 times seizure threshold for unilateral ECT and 1.5 times seizure threshold for bilateral ECT. RESULTS: Seventy-two (15%) of the 471 patients required the maximum stimulus intensity during their index ECT course. Of these, 24 (5% of the total) had either a short EEG seizure (less than 25 seconds) or had no seizure at the maximum level. Strategies to augment therapeutic response with caffeine, ketamine, or hyperventilation were used in 14 of the 24 patients, and data on therapeutic response were available for 22 of the 24. Only seven (32%) of these 22 patients were considered ECT responders, compared with 242 (66%) of the remaining 364 patients for whom data on response to ECT were available. Older age and pre-ECT course EEG slowing were predictors of requiring the maximum stimulus level. CONCLUSIONS: The maximum available stimulus output was therapeutically insufficient for 5% of the patients studied even when available means to augment response were instituted. This percentage would likely be even larger with the use of a less conservative dosing protocol for unilateral ECT. Increases in maximum stimulus output for ECT devices should be considered as a means to ensure adequate treatment response.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1176/appi.ajp.157.6.963

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 54

Metadata

Authors
Krystal, A. D., Dean, M. D., Weiner, R. D., Tramontozzi, L. A., Connor, K. M., Lindahl, V. H., & Massie, R. W.
Venue
American Journal of Psychiatry
Published
2000-06-01
Volume
157
Issue
6
Pages
963-967
ISSN
  • 0002-953X (ISSN-L)
  • 1535-7228
OpenAlex
W2164728490
Cited by
54
References
0
FWCI
3.79
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: ECT Stimulus Intensity: Are Present ECT Devices Too Limited? https://app.cochat.ai/papers/10.1176/appi.ajp.157.6.963
The paper
Krystal, A. D., Dean, M. D., Weiner, R. D., Tramontozzi, L. A., Connor, K. M., Lindahl, V. H., & Massie, R. W. (2000). ECT Stimulus Intensity: Are Present ECT Devices Too Limited? American Journal of Psychiatry. https://doi.org/10.1176/appi.ajp.157.6.963

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.