Measuring Ankle Systolic Blood Pressure: Validation of the Dinamap 1846 SX

Mundt, Kenneth A., Chambless, Lloyd E., Burnham, Cynthia B., Heiss, Gerardo · 1992 · Angiology
Cited by 77

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Clinical and epidemiologic situations requiring repeated measurements of blood pressure in the lower extremity are increasingly incorporating automated measurement devices; however, no device has been validated adequately for ankle blood pressure. This study evaluates the Dinamap 1846 SX against Dop pler ultrasound in determining ankle systolic blood pressure (SBP) and com pares a parallel with contour wrapping technique for applying the blood pres sure cuff. Ankle SBP was measured on 71 adult volunteers by both devices simultaneously, for each cuff wrap. Averages of three readings were compared to evaluate Dinamap versus Doppler SBP estimates and to assess any cuff wrap effect. Multiple linear regression was used to assess potential effect modifiers. Instrument differences (Dinamap minus Doppler) for the parallel wrap (95% confidence intervals in parenthesis) were —1.5 mmHg (-3.1, 0.0) and — 3.9 mmHg (-5.6, -2.2) for the contour wrap. Wrap effect differences (contour minus parallel) for the Doppler were -4.9 mmHg (-6.3, -3.5) and -7.2 mmHg ( — 8.7, — 5.8) for the Dinamap. Degree of ankle taper was a strong modi fier of cuff effect for the Dinamap but not for the Doppler: adjusted cuff effect with the Dinamap ranged from — 3 to —10 mmHg. Measurement precision (within-person reproducibility, measured by within-person standard deviation [σ 2] and reliability coefficient [R]) was higher for the Dinamap than the Doppler technique, lowest for the parallel wrap and Doppler configuration (σ 2 = 5.4 mmHg, R = 0.88) and greatest for the contour wrap and Dinamap (σ 2 = 4.0 mmHg, R = 0.94). In conclusion, cuff-wrapping technique can generate SBP differences of greater magnitude than instrument differences. Conditional on the use of the contour wrap, and by virtue of its high repeatability and ease of operation, the Dinamap is a useful tool for epidemiologic study and the clinical assessment of peripheral arterial disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/000331979204300703

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 77

Metadata

Authors
Mundt, K. A., Chambless, L. E., Burnham, C. B., & Heiss, G.
Venue
Angiology
Published
1992-07
Volume
43
Issue
7
Pages
555-566
ISSN
  • 0003-3197 (ISSN-L)
  • 1940-1574
OpenAlex
W2033795378
Cited by
77
References
1
FWCI
0.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measuring Ankle Systolic Blood Pressure: Validation of the Dinamap 1846 SX. https://app.cochat.ai/papers/10.1177/000331979204300703
The paper
Mundt, K. A., Chambless, L. E., Burnham, C. B., & Heiss, G. (1992). Measuring Ankle Systolic Blood Pressure: Validation of the Dinamap 1846 SX. Angiology. https://doi.org/10.1177/000331979204300703

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.