The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Histopathology of Cochlear Implants in Humans
Abstract
The insertion of an intrascalar electrode array during cochlear implantation causes immediate damage to the inner ear and may result in delayed onset of additional damage that may interfere with neuronal stimulation. To date, there have been reports on fewer than 50 temporal bone specimens from patients who had undergone implantation during life. The majority of these were single-channel implants, whereas the majority of implants inserted today are multichannel systems. This report presents the histopathologic findings in temporal bones from 8 individuals who in life had undergone multichannel cochlear implantation, with particular attention to the type and location of trauma and to long-term changes within the cochlea. The effect of these changes on spiral ganglion cell counts and the correlation between speech comprehension and spiral ganglion cell counts were calculated. In 4 of the 8 cases, the opposite, unimplanted ear was available for comparison. In 3 of the 4 cases, there was no significant difference between the spiral ganglion cell counts on the implanted and unimplanted sides. In addition, in this series of 8 cases, there was an apparent negative correlation between residual spiral ganglion cell count and hearing performance during life as measured by single-syllable word recognition. This finding suggests that abnormalities in the central auditory pathways are at least as important as spiral ganglion cell loss in limiting the performance of implant users.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Schuknecht, H. F. (1974) · Medical Entomology and Zoology · Cited by 1,222
Leake, P. A., Hradek, G. T., Rebscher, S. J., & Snyder, R. L. (1991) · Hearing Research · doi:10.1016/0378-5955(91)90120-x · Cited by 206
A graphic reconstruction method for the study of the organ of Corti
Guild, S. R. (1921) · The Anatomical Record · doi:10.1002/ar.1090220205 · Cited by 191
Shepherd, R. K., Clark, G. M., & Black, R. C. (1983) · Acta Oto-Laryngologica · doi:10.3109/00016488309105589 · Cited by 148
Cochlear implant histopathology.
Linthicum, F. H., Fayad, J. N., Otto, S. R., Galey, F. R., & House, W. F. (1991) · PubMed · Cited by 143
Increased spiral ganglion cell survival in electrically stimulated, deafened guinea pig cochleae
Lousteau, R. J. (1987) · The Laryngoscope · doi:10.1288/00005537-198707000-00012 · Cited by 133
Protective effect of electrical stimulation in the deafened guinea pig cochlea
Hartshorn, D. O., Miller, J. M., & Altschuler, R. A. (1991) · Otolaryngology · doi:10.1177/019459989110400305 · Cited by 120
Banded Intracochlear Electrode Array: Evaluation of Insertion Trauma in Human Temporal Bones
Shepherd, R. K., Pyman, B. C., Clark, G. M., et al. (1985) · Annals of Otology Rhinology & Laryngology · doi:10.1177/000348948509400112 · Cited by 115
Mitchell, A. N., Miller, J. M., Finger, P. A., Heller, J. W., Raphael, Y., & Altschuler, R. A. (1997) · Hearing Research · doi:10.1016/s0378-5955(96)00202-x · Cited by 109
Cochlear Implant Deep Electrode Insertion: Extent of Insertional Trauma
Gstoettner, W. K., Plenk, H., Jr., Franz, P., Hamzavi, J. S., Baumgartner, W., Czerny, C., & Ehrenberger, K. (1997) · Acta Oto-Laryngologica · doi:10.3109/00016489709117786 · Cited by 105
Cited by
Cochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878
Cochlear implants: A remarkable past and a brilliant future
Wilson, B. S., & Dorman, M. F. (2008) · Hearing Research · doi:10.1016/j.heares.2008.06.005 · Cited by 868
Role of Electrode Placement as a Contributor to Variability in Cochlear Implant Outcomes
Finley, C. C., Holden, T. A., Holden, L. K., Whiting, B. R., Chole, R. A., Neely, G. J., Hullar, T. E., & Skinner, M. W. (2008) · Otology & Neurotology · doi:10.1097/mao.0b013e318184f492 · Cited by 549
Zeng, F.-G. (2004) · Trends in Amplification · doi:10.1177/108471380400800102 · Cited by 401
Cochlear implants: Current designs and future possibilities
Wilson, B. S. (2008) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2007.10.0173 · Cited by 396
Metadata
- Authors
- Nadol, J. B., Burgess, B. J., Gantz, B. J., Coker, N. J., Ketten, D. R., Kos, I., Roland, J. T., Shiao, J. Y., Eddington, D. K., Montandon, P., & Shallop, J. K.
- Venue
- Annals of Otology, Rhinology & Laryngology
- Publisher
- SAGE Publications
- Published
- 2001-09
- Volume
- 110
- Issue
- 9
- Pages
- 883-891
- ISSN
- 0003-4894 (ISSN-L)
- 1943-572X
- OpenAlex
- W2052862243
- Cited by
- 292
- References
- 15
- FWCI
- 4.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Histopathology of Cochlear Implants in Humans. https://app.cochat.ai/papers/10.1177/000348940111000914
- The paper
- Nadol, J. B., Burgess, B. J., Gantz, B. J., Coker, N. J., Ketten, D. R., Kos, I., Roland, J. T., Shiao, J. Y., Eddington, D. K., Montandon, P., & Shallop, J. K. (2001). Histopathology of Cochlear Implants in Humans. Annals of Otology, Rhinology & Laryngology. https://doi.org/10.1177/000348940111000914
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.