Histopathology of Cochlear Implants in Humans
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
The insertion of an intrascalar electrode array during cochlear implantation causes immediate damage to the inner ear and may result in delayed onset of additional damage that may interfere with neuronal stimulation. To date, there have been reports on fewer than 50 temporal bone specimens from patients who had undergone implantation during life. The majority of these were single-channel implants, whereas the majority of implants inserted today are multichannel systems. This report presents the histopathologic findings in temporal bones from 8 individuals who in life had undergone multichannel cochlear implantation, with particular attention to the type and location of trauma and to long-term changes within the cochlea. The effect of these changes on spiral ganglion cell counts and the correlation between speech comprehension and spiral ganglion cell counts were calculated. In 4 of the 8 cases, the opposite, unimplanted ear was available for comparison. In 3 of the 4 cases, there was no significant difference between the spiral ganglion cell counts on the implanted and unimplanted sides. In addition, in this series of 8 cases, there was an apparent negative correlation between residual spiral ganglion cell count and hearing performance during life as measured by single-syllable word recognition. This finding suggests that abnormalities in the central auditory pathways are at least as important as spiral ganglion cell loss in limiting the performance of implant users.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Schuknecht, H. F. (1974) · Medical Entomology and Zoology · Cited by 1,222
Leake, P. A., Hradek, G. T., Rebscher, S. J., & Snyder, R. L. (1991) · Hearing Research · doi:10.1016/0378-5955(91)90120-x · Cited by 206
A graphic reconstruction method for the study of the organ of Corti
Guild, S. R. (1921) · The Anatomical Record · doi:10.1002/ar.1090220205 · Cited by 191
Shepherd, R. K., Clark, G. M., & Black, R. C. (1983) · Acta Oto-Laryngologica · doi:10.3109/00016488309105589 · Cited by 146
Cochlear implant histopathology.
Linthicum, F. H., Fayad, J. N., Otto, S. R., Galey, F. R., & House, W. F. (1991) · PubMed · Cited by 143
Increased spiral ganglion cell survival in electrically stimulated, deafened guinea pig cochleae
Lousteau, R. J. (1987) · The Laryngoscope · doi:10.1288/00005537-198707000-00012 · Cited by 141
Banded Intracochlear Electrode Array: Evaluation of Insertion Trauma in Human Temporal Bones
Shepherd, R. K., Pyman, B. C., Clark, G. M., & Webb, R. L. (1985) · Annals of Otology Rhinology & Laryngology · doi:10.1177/000348948509400112 · Cited by 128
Protective effect of electrical stimulation in the deafened guinea pig cochlea
Hartshorn, D. O., Miller, J. M., & Altschuler, R. A. (1991) · Otolaryngology–Head and Neck Surgery · doi:10.1177/019459989110400305 · Cited by 120
Mitchell, A. N., Miller, J. M., Finger, P. A., Heller, J. W., Raphael, Y., & Altschuler, R. A. (1997) · Hearing Research · doi:10.1016/s0378-5955(96)00202-x · Cited by 109
Cochlear Implant Deep Electrode Insertion: Extent of Insertional Trauma
Gstoettner, W. K., Plenk, H., Jr., Franz, P., Hamzavi, J. S., Baumgartner, W., Czerny, C., & Ehrenberger, K. (1997) · Acta Oto-Laryngologica · doi:10.3109/00016489709117786 · Cited by 105
Cited by
Cochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878
“perimodiolar position adjacent to less damaged neurons [140], [151]–[155].”
BackgroundCochlear implants: A remarkable past and a brilliant future
Wilson, B. S., & Dorman, M. F. (2008) · Hearing Research · doi:10.1016/j.heares.2008.06.005 · Cited by 868
Role of Electrode Placement as a Contributor to Variability in Cochlear Implant Outcomes
Finley, C. C., Holden, T. A., Holden, L. K., Whiting, B. R., Chole, R. A., Neely, G. J., Hullar, T. E., & Skinner, M. W. (2008) · Otology & Neurotology · doi:10.1097/mao.0b013e318184f492 · Cited by 549
Zeng, F.-G. (2004) · Trends in Amplification · doi:10.1177/108471380400800102 · Cited by 401
Cochlear implants: Current designs and future possibilities
Wilson, B. S. (2008) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2007.10.0173 · Cited by 396
The cochlear implant: historical aspects and future prospects
Eshraghi, A. A., Nazarian, R., Telischi, F. F., Rajguru, S. M., Truy, E., & Gupta, C. (2012) · The Anatomical Record · doi:10.1002/ar.22580 · Cited by 285
“…trauma caused to the cochlea from different multichannel cochlear implant electrodes (O’Leary et al., 1991; Welling et al., 1993; Gstoettner, 1997; Nadol et al., 2001; Adunka et al., 2004; Gstoettner et al., 2004; Roland, 2005; Fraysse et al., 2006; Rebscher et al., 2008; Helbig et al., 2011).”
BackgroundTechnological, biological, and acoustical constraints to music perception in cochlear implant users
Limb, C. J., & Roy, A. T. (2014) · Hearing Research · doi:10.1016/j.heares.2013.04.009 · Cited by 274
Comparative Study of Cochlear Damage With Three Perimodiolar Electrode Designs
Eshraghi, A. A., Yang, N. W., & Balkany, T. J. (2003) · The Laryngoscope · doi:10.1097/00005537-200303000-00005 · Cited by 257
Cortical Activity at Rest Predicts Cochlear Implantation Outcome
Lee, H.-J., Giraud, A.-L., Kang, E., Oh, S.-H., Kang, H., Kim, C.-S., & Lee, D. S. (2007) · Cerebral Cortex · doi:10.1093/cercor/bhl001 · Cited by 236
Multichannel Cochlear Implants: Relation of Histopathology to Performance
Fayad, J. N., & Linthicum, F. H. (2006) · The Laryngoscope · doi:10.1097/01.mlg.0000227176.09500.28 · Cited by 222
Pathophysiological mechanisms and functional hearing consequences of auditory neuropathy
Rance, G., & Starr, A. (2015) · Brain · doi:10.1093/brain/awv270 · Cited by 212
“…aware of ‘hearing’ impairments affecting the auditory nerve due to infections (e.g. lues), neoplasms (e.g. acoustic neuroma, brainstem meningiomas) and hereditary neuropathies (e.g. Friedreich ataxia and Charcot–Marie–Tooth disease) (Spoendlin 1974; Hallpike et al ., 1980; Nadol et al ., 2001).”
Intracochlear Inflammatory Response to Cochlear Implant Electrodes in Humans
Seyyedi, M., & Nadol, J. B. (2014) · Otology & Neurotology · doi:10.1097/mao.0000000000000540 · Cited by 201
“It has also been suggested that the severity of local tissue response may be inversely correlated with survival of the spiral ganglion cells (19), performance after implantation, and preservation of the residual acoustic hearing (28,29).”
BackgroundResultSelf-citationDeafness-Induced Changes in the Auditory Pathway: Implications for Cochlear Implants
Shepherd, R. K., & Hardie, N. A. (2001) · Audiology and Neurotology · doi:10.1159/000046843 · Cited by 189
Relations between cochlear histopathology and hearing loss in experimental cochlear implantation
O'Leary, S. J., Monksfield, P., Kel, G., Connolly, T., Souter, M. A., Chang, A., Marovic, P., O'Leary, J. S., Richardson, R., & Eastwood, H. (2013) · Hearing Research · doi:10.1016/j.heares.2013.01.012 · Cited by 187
Rebscher, S. J. (2008) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2007.08.0119 · Cited by 169
Cochlear-implant spatial selectivity with monopolar, bipolar and tripolar stimulation
Zhu, Z., Tang, Q., Zeng, F.-G., Guan, T., & Ye, D. (2012) · Hearing Research · doi:10.1016/j.heares.2011.11.005 · Cited by 115
Toward a self-deploying shape memory polymer neuronal electrode
Sharp, A. A., Panchawagh, H. V., Ortega, A., Artale, R., Richardson-Burns, S., Finch, D. S., Gall, K., Mahajan, R. L., & Restrepo, D. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/l02 · Cited by 113
Metadata
- Authors
- Nadol, J. B., Burgess, B. J., Gantz, B. J., Coker, N. J., Ketten, D. R., Kos, I., Roland, J. T., Shiao, J. Y., Eddington, D. K., Montandon, P., & Shallop, J. K.
- Venue
- Annals of Otology, Rhinology & Laryngology
- Publisher
- SAGE Publications
- Published
- 2001-09
- Volume
- 110
- Issue
- 9
- Pages
- 883-891
- ISSN
- 0003-4894 (ISSN-L)
- 1943-572X
- OpenAlex
- W2052862243
- Cited by
- 292
- References
- 15
- FWCI
- 4.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.