Spectral-Cepstral Estimation of Dysphonia Severity: External Validation
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Objectives: The current study applied an acoustic algorithm incorporating measures from cepstral and spectral analyses, the Cepstral Spectral Index of Dysphonia (CSID), in an attempt to externally validate the CSID as an acoustic estimate of dysphonia severity. Methods: Correlation (Pearson's r) between the CSID and trained listener-perceived severities as rated on the Consensus Auditory-Perceptual Evaluation of Voice (CAPE-V) was calculated from sentence and sustained vowel samples from 56 patients before or after they underwent thyroid surgery. Results: A strong correlation was identified between the mean CSID values calculated across CAPE-V sentences and vowels and the median rating of perceived overall severity ( r = 0.82; p < 0.001). The CSID values did not differ significantly from their corresponding auditory-perceptual ratings of dysphonia severity for these samples (CSID: Mean, 15.54, SD, 16.63; CAPE-V Severity: Mean, 17.33, SD, 13.61; p = 0.16). Conclusions: Independent testing of an acoustic algorithm incorporating measures from cepstral and spectral analyses (the CSID) confirmed a strong correlation of the CSID to perceptual ratings of overall voice quality. This study provides external validation of the CSID as a robust correlate of dysphonia severity as rated by trained listeners.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Maryn, Y., Corthals, P., Van Cauwenberge, P., Roy, N., & De Bodt, M. (2010) · Journal of Voice · doi:10.1016/j.jvoice.2008.12.014 · Cited by 427
Task specificity in adductor spasmodic dysphonia versus muscle tension dysphonia
Roy, N., Gouse, M., Mauszycki, S. C., Merrill, R. M., & Smith, M. E. (2005) · The Laryngoscope · doi:10.1097/01.mlg.0000154739.48314.ee · Cited by 113
Cited by
Maryn, Y., & Weenink, D. (2015) · Journal of Voice · doi:10.1016/j.jvoice.2014.06.015 · Cited by 271
Assessment of voice quality: Current state-of-the-art
Barsties, B., & De Bodt, M. (2015) · Auris Nasus Larynx · doi:10.1016/j.anl.2014.11.001 · Cited by 265
Roy, N., Mazin, A., & Awan, S. N. (2014) · The Laryngoscope · doi:10.1002/lary.24362 · Cited by 54
Self-citationJayakumar, T., Rajasudhakar, R., & Benoy, J. J. (2024) · Journal of Voice · doi:10.1016/j.jvoice.2022.02.019 · Cited by 8
Validation of Acoustic Breathiness Index (ABI) in the South Indian Population
Jayakumar, T., & Benoy, J. J. (2024) · Journal of Voice · doi:10.1016/j.jvoice.2022.05.006 · Cited by 8
Metadata
- Authors
- Awan, S. N., Solomon, N. P., Helou, L. B., & Stojadinovic, A.
- Venue
- Annals of Otology, Rhinology & Laryngology
- Publisher
- SAGE Publications
- Published
- 2013-01
- Volume
- 122
- Issue
- 1
- Pages
- 40-48
- ISSN
- 0003-4894 (ISSN-L)
- 1943-572X
- OpenAlex
- W2315994507
- Cited by
- 76
- References
- 3
- FWCI
- 2.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Spectral-Cepstral Estimation of Dysphonia Severity: External Validation. https://app.cochat.ai/papers/10.1177/000348941312200108
- The paper
- Awan, S. N., Solomon, N. P., Helou, L. B., & Stojadinovic, A. (2013). Spectral-Cepstral Estimation of Dysphonia Severity: External Validation. Annals of Otology, Rhinology & Laryngology. https://doi.org/10.1177/000348941312200108
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.