Responses of Cat Auditory Nerve Fibers to Biphasic Electrical Current Pulses
The DOI matches its Crossref record.
Abstract
Discharge patterns of single auditory nerve fibers were recorded from normal-hearing cats implanted with a 12-band intracochlear electrode array. Stimuli were biphasic current pulses of specifiable width, amplitude, and rate. Acoustic tuning curves were obtained to determine the cochlear positions of the fibers. Response latencies to electrical stimuli formed two groups. Short latency (0.3 to 0.7 ms) responses were attributed to direct activation of spiral ganglion neurons. At high stimulus intensities, these often exhibited abrupt shifts toward even shorter latencies. Long latency (> 1.5 ms) responses were probably caused by electrophonic activation of functional hair cells. Response thresholds to electrical stimuli depended on a fiber's proximity to the stimulating electrodes, and they did not depend on a fiber's acoustic response threshold or spontaneous discharge rate. High intensity (> 1.5 mA) stimuli could excite fibers over a wide range of characteristic frequencies, even for the narrowest (0.45 mm) electrode separations. Response threshold was an exponentially decreasing function of pulse width for widths up to 300 μs/phase. Fiber discharges were highly phase-locked at all suprathreshold intensities, and saturation discharge rates usually equaled stimulus pulse rates for rates up to at least 800 pulses/s. Dynamic ranges were small (1 to 6 dB), increased with pulse rate, and were uncorrelated with electrical response threshold. Within the dynamic range, shapes of poststimulus time and interspike interval histograms resembled those obtained in response to acoustic stimuli. Depolarization block caused fiber activity to cease in 2 to 5 seconds for sustained stimuli presented at high (> 600 pulses/s) pulse rates and intensities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrical stimulation of the auditory nerve: The effect of electrode position on neural excitation
Shepherd, R. K., Hatsushika, S., & Clark, G. M. (1993) · Hearing Research · doi:10.1016/0378-5955(93)90265-3 · Cited by 360
Self-citationVandali, A. E., Whitford, L. A., Plant, K. L., & Clark, A. G. M. (2000) · Ear and Hearing · doi:10.1097/00003446-200012000-00008 · Cited by 308
Shepherd, R. K., & Javel, E. (1997) · Hearing Research · doi:10.1016/s0378-5955(97)00046-4 · Cited by 292
Self-citationNerve conduction block utilising high-frequency alternating current
Kilgore, K. L., & Bhadra, N. (2004) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344716 · Cited by 284
Xu, J., Shepherd, R. K., Millard, R. E., & Clark, G. M. (1997) · Hearing Research · doi:10.1016/s0378-5955(96)00193-1 · Cited by 242
“Given sufficient stimulus intensity, auditory nerve fibres are capable -- at least for short periods of time -of discharging in response to every current pulse at stimulus rates far beyond their normal maximum physiological rate (Moxon, 1971; Hartmann et al., 1984; van den Honert and Stypulkowski, 1984; Javel et al.,…”
BackgroundSelf-citation
Metadata
- Authors
- Javel, E., Tong, Y. C., Shepherd, R. K., & Clark, G. M.
- Venue
- Annals of Otology, Rhinology & Laryngology
- Publisher
- SAGE Publications
- Published
- 1987-01
- Volume
- 96
- Issue
- 1_suppl
- Pages
- 26-30
- ISSN
- 0003-4894 (ISSN-L)
- 1943-572X
- OpenAlex
- W2163074833
- Cited by
- 123
- References
- 0
- FWCI
- 4.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Responses of Cat Auditory Nerve Fibers to Biphasic Electrical Current Pulses. https://app.cochat.ai/papers/10.1177/00034894870960s111
- The paper
- Javel, E., Tong, Y. C., Shepherd, R. K., & Clark, G. M. (1987). Responses of Cat Auditory Nerve Fibers to Biphasic Electrical Current Pulses. Annals of Otology, Rhinology & Laryngology. https://doi.org/10.1177/00034894870960s111
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.