The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Speech Perception as a Function of Electrical Stimulation Rate: Using the Nucleus 24 Cochlear Implant System
Abstract
OBJECTIVE: To investigate the effect of varying electrical stimulation rate on speech comprehension by cochlear implant users, while keeping the number of stimulated channels constant. DESIGN: Three average rates of electrical stimulation, 250, 807, and 1615 pulses per second per channel (pps/ch), were compared using a speech processing strategy that employed an electrode selection technique similar to that used in the Spectral Maxima Sound Processor strategy (McDermott, McKay, & Vandali, 1992; McDermott & Vandali, Reference Note 1; McKay, McDermott, Vandali, & Clark, 1991) and the Spectral Peak strategy (Skinner et al., 1994; Whitford et al., 1995). Speech perception tests with five users of the Nucleus 24 cochlear implant system were conducted over a 21-wk period. Subjects were given take-home experience with each rate condition. A repeated ABC evaluation protocol with alternating order was employed so as to account for learning effects and to minimize order effects. Perception of open-set monosyllabic words in quiet and open-set sentences at signal to noise ratios ranging from +20 to 0 dB, depending on the subject's ability, were tested. A comparative performance questionnaire was also administered. RESULTS: No statistical differences in group performance between the 250 and 807 pps/ch rates were observed in any of the speech perception tests. However, significantly poorer group performance was observed for the 1615 pps/ch rate for some tests due predominantly to the results of one subject. Analysis of individual scores showed considerable variation across subjects. For some subjects, one or more of the three rate conditions evaluated provided benefits on some speech perception tasks. The results of the comparative performance questionnaire indicated a preference for the 250 and 807 pps/ch rates over the 1615 pps/ch rate for most listening situations. CONCLUSIONS: For the speech processing strategy, implant system, and subjects evaluated in this study, the group results indicated that the use of electrical stimulation rates higher than 250 pps/ch (up to 1615 pps/ch) generally provided no significant improvement to speech comprehension. However, individual results indicated that perceptual benefits could be obtained by adjusting rate of stimulation optimally to suit each subject. Results from one subject, together with tinnitus problems arising from high-rate stimulation for another subject, indicated that high rates of stimulation may in fact be undesirable for some subjects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SCHEFFE, H. (1960) · Soil Science · doi:10.1097/00010694-196006000-00016 · Cited by 5,516
Speech Recognition with Primarily Temporal Cues
Shannon, R. V., Zeng, F.-G., Kamath, V., Wygonski, J., & Ekelid, M. (1995) · Science · doi:10.1126/science.270.5234.303 · Cited by 3,024
Better speech recognition with cochlear implants
Wilson, B. S., Finley, C. C., Lawson, D. T., Wolford, R. D., Eddington, D. K., & Rabinowitz, W. M. (1991) · Nature · doi:10.1038/352236a0 · Cited by 1,190
Electrical Stimulation of the Auditory Nerve in Man
SIMMONS, F. B. (1966) · Archives of Otolaryngology - Head and Neck Surgery · doi:10.1001/archotol.1966.00760030004003 · Cited by 613
Intonation, Perception and Language
Pollack, I., & Lieberman, P. (1968) · The American Journal of Psychology · doi:10.2307/1421071 · Cited by 594
Multichannel electrical stimulation of the auditory nerve in man. I. Basic psychophysics
Shannon, R. V. (1983) · Hearing Research · doi:10.1016/0378-5955(83)90077-1 · Cited by 364
Intonation and the perceptual separation of simultaneous voices
Brokx, J. P. L., & Nooteboom, S. G. (1982) · Journal of Phonetics · doi:10.1016/s0095-4470(19)30909-x · Cited by 364
Auditory Prostheses Research with Multiple Channel Intracochlear Stimulation in Man
Eddington, D. K., Dobelle, W. H., Mladejovsky, M. G., Brackmann, D. E., & Parkin, J. L. (1978) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/00034894780870s602 · Cited by 334
Pitch perception by cochlear implant subjects
Townshend, B., Cotter, N., Van Compernolle, D., & White, R. L. (1987) · The Journal of the Acoustical Society of America · doi:10.1121/1.395554 · Cited by 306
Speech waveform envelope cues for consonant recognition
Van Tasell, D. J., Soli, S. D., Kirby, V. M., & Widin, G. P. (1987) · The Journal of the Acoustical Society of America · doi:10.1121/1.395251 · Cited by 292
Cited by
Cochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878
Music Perception with Cochlear Implants: A Review
McDermott, H. J. (2004) · Trends in Amplification · doi:10.1177/108471380400800203 · Cited by 549
Temporal considerations for stimulating spiral ganglion neurons with cochlear implants.
Boulet, J., White, M., & Bruce, I. C. (2016) · Journal of the Association for Research in Otolaryngology · doi:10.1007/s10162-015-0545-5 · Cited by 114
Metadata
- Authors
- Vandali, A. E., Whitford, L. A., Plant, K. L., & Clark, A. G. M.
- Venue
- Ear and Hearing
- Published
- 2000-12
- Volume
- 21
- Issue
- 6
- Pages
- 608-624
- ISSN
- 0196-0202 (ISSN-L)
- OpenAlex
- W1991298420
- Cited by
- 308
- References
- 33
- FWCI
- 3.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Speech Perception as a Function of Electrical Stimulation Rate: Using the Nucleus 24 Cochlear Implant System. https://app.cochat.ai/papers/10.1097/00003446-200012000-00008
- The paper
- Vandali, A. E., Whitford, L. A., Plant, K. L., & Clark, A. G. M. (2000). Speech Perception as a Function of Electrical Stimulation Rate: Using the Nucleus 24 Cochlear Implant System. Ear and Hearing. https://doi.org/10.1097/00003446-200012000-00008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.