CoChat

Comparison of method-related reference intervals for thyroid hormones: studies from a prospective reference population and a literature review

Barth, Julian H, Luvai, Ahai, Jassam, Nuthar, Mbagaya, Wycliffe, Kilpatrick, Eric S, Narayanan, Deepa, Spoors, Shirley · 2018 · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Introduction: Reference intervals are dependent on the reference population, the analytical methods and the way the data are handled statistically. Individual method-related differences have been studied but the comparative differences in reference intervals have not. Methods: We studied a reference population of healthy adult subjects and measured free thyroxine and thyroid-stimulating hormone by the four most commonly used analytical platforms used in the UK. Subjects were excluded if they were > 65 years or had positive thyroid peroxidase antibodies. We also performed a systematic literature review of thyroid hormone reference interval studies in non-pregnant adults. Results: In total, 303 subjects were recruited and 42 excluded. The central 95th centile values for thyroid-stimulating hormone (mIU/L) were Abbott Architect (0.51–3.67); Beckman Unicel DxI (0.57–3.60); Roche Cobas (0.60–4.31) and Siemens Advia Centaur XP (0.63–4.29). The 95th centile values for thyroxine (pmol/L) were Abbott Architect (10.6–15.5); Beckman Unicel DxI (7.9–13.0); Roche Cobas (12.5–19.6) and Siemens Advia Centaur XP (11.8–19.0). We identified 55 papers describing thyroid reference intervals in male and non-pregnant female adults. The values for upper and lower reference intervals by manufacturer varied but were not significantly different for thyroid-stimulating hormone but were for thyroxine. Discussion: Our study demonstrates clearly that there are marked variations in the reference intervals for thyroid hormones between analytical platforms. There is an urgent need for standardization of thyroid hormone assays to permit transferability of results. Until then, guidelines will need to reflect this method-related difference.

Overview

Integrity signals

Registry

Crossref · 10.1177/0004563217691549

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 10 references

Research works printed but not linked: 1

  1. Jones GR, 2014, Clin Biochem Rev, 35, 243

Cited by

See all 54

Metadata

Authors
Barth, J. H., Luvai, A., Jassam, N., Mbagaya, W., Kilpatrick, E. S., Narayanan, D., & Spoors, S.
Affiliations
  • Leeds General Infirmary (GB)
  • Harrogate District Hospital (GB)
  • Hull Royal Infirmary (GB)
  • Doncaster Royal Infirmary (GB)
Corresponding author
Barth, Julian H
Venue
Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
Published
2017-05-08
Volume
55
Issue
1
Pages
107-112
ISSN
  • 0004-5632 (ISSN-L)
  • 1758-1001
OpenAlex
W2573405579
Cited by
53
References
10
Citations by year
2026: 6 · 2025: 5 · 2024: 5 · 2023: 10 · 2022: 5 · 2021: 14 · 2020: 5 · 2019: 3
FWCI
1.62
Type
journal article
Language
en
Open access
closed
Licence
journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
Locations
  • Annals of Clinical Biochemistry International Journal of Laboratory Medicine (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Thyroid Disorders and Treatments
  • Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
Keywords
free thyroxine, thyroid-stimulating hormone, assay standardization, transferability of results
MeSH terms
Adult, Female, United Kingdom, Humans, Male, Prospective Studies, Reference Values, Thyroid Hormones

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of method-related reference intervals for thyroid hormones: studies from a prospective reference population and a literature review. https://app.cochat.ai/papers/10.1177/0004563217691549
The paper
Barth, J. H., Luvai, A., Jassam, N., Mbagaya, W., Kilpatrick, E. S., Narayanan, D., & Spoors, S. (2018). Comparison of method-related reference intervals for thyroid hormones: studies from a prospective reference population and a literature review. Annals of Clinical Biochemistry: International Journal of Laboratory Medicine. https://doi.org/10.1177/0004563217691549

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.