CoChat

Electrocutaneous Pulse Rate and Pulse Width Psychometric Functions for Sensory Communications

Szeto, Andrew Y. J., Lyman, John, Prior, Ronald E. · 1979 · Human Factors: The Journal of the Human Factors and Ergonomics Society
Cited by 46

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Psychometric functions of pulse rate (PR) and pulse width (PW) from electrocutaneous stimuli were determined using the method of comparative judgments. The study revealed that changes in PR were more easily detected than changes in PW, as measured by the percent of just noticeable difference (jnd). The PR jnd data from test subjects indicated that maximum frequency discrimination occurred near 20 pulses per second. Using the PR and PW psychometric curves, compensatory transfer functions can be determined which will improve the efficacy of sensory communication systems based on electrocutaneous stimulation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/001872087902100212

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 46

Metadata

Authors
Szeto, A. Y. J., Lyman, J., & Prior, R. E.
Venue
Human Factors: The Journal of the Human Factors and Ergonomics Society
Published
1979-04
Volume
21
Issue
2
Pages
241-249
ISSN
  • 0018-7208 (ISSN-L)
  • 1547-8181
OpenAlex
W1547536492
Cited by
46
References
1
FWCI
0.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electrocutaneous Pulse Rate and Pulse Width Psychometric Functions for Sensory Communications. https://app.cochat.ai/papers/10.1177/001872087902100212
The paper
Szeto, A. Y. J., Lyman, J., & Prior, R. E. (1979). Electrocutaneous Pulse Rate and Pulse Width Psychometric Functions for Sensory Communications. Human Factors: The Journal of the Human Factors and Ergonomics Society. https://doi.org/10.1177/001872087902100212

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.