Cited by 74Neuroscience and Neural EngineeringMuscle activation and electromyography studiesTactile and Sensory Interactions

Human ability to discriminate various parameters in afferent electrical nerve stimulation with particular reference to prostheses sensory feedback

Anani, A. B., Ikeda, K., Körner, L. M.·1977·Medical & Biological Engineering & Computing

Integrity signals

Registry

Crossref · 10.1007/bf02457988

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Anani et al. stimulated median and radial nerves of able-bodied subjects with an effective stimulation time of 17%; although threshold changes made an up-regulation of parameters necessary in some cases, no indication of permanent damage was reported.

    “In an early acute study, Anani et al. stimulated median and radial nerves of able-bodied subjects with an effective stimulation time of 17%. Although threshold changes made an up-regulation of parameters necessary in some cases, no indication of permanent damage was reported [97].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Anani, A. B., Ikeda, K., & Körner, L. M.
Affiliations
Sahlgrenska University Hospital (SE)
Venue
Medical & Biological Engineering & Computing
Published
1977-07
Volume
15
Issue
4
Pages
363-373
ISSN
  • 0140-0118 (ISSN-L)
  • 1741-0444
OpenAlex
W1968532283
Cited by
74
References
19
Citations by year
2024: 1 · 2023: 4 · 2022: 6 · 2021: 2 · 2020: 5 · 2019: 1 · 2018: 2 · 2017: 3 · 2016: 4 · 2015: 9 · 2014: 5 · 2013: 3 · 2012: 4
FWCI
1.38
Type
journal article
Language
en
Open access
closed
Locations
  • Medical & Biological Engineering & Computing (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
Keywords
sensory feedback, powered prostheses, paresthesia, information transfer rate, electrode placement
MeSH terms
Adult, Discrimination, Psychological, Electric Stimulation, Feedback, Female, Humans, Male, Neurons, Afferent, Prosthesis Design

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review