Human ability to discriminate various parameters in afferent electrical nerve stimulation with particular reference to prostheses sensory feedback
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Anani et al. stimulated median and radial nerves of able-bodied subjects with an effective stimulation time of 17%; although threshold changes made an up-regulation of parameters necessary in some cases, no indication of permanent damage was reported.
“In an early acute study, Anani et al. stimulated median and radial nerves of able-bodied subjects with an effective stimulation time of 17%. Although threshold changes made an up-regulation of parameters necessary in some cases, no indication of permanent damage was reported [97].”
From Safety of long-term electrical peripheral nerve stimulation: review of the state of the art (2019) · cites this paper as [97]
Cites
Information Transmission by Phantom Sensations
Alles, D. S. (1970) · IEEE Transactions on Man Machine Systems · doi:10.1109/tmms.1970.299967 · Cited by 272 · see citing works
Experimental correction of footdrop by electrical stimulation of the peroneal nerve
Waters, R. L., McNeal, D. R., & Perry, J. (1975) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-197557080-00002 · Cited by 152 · see citing works
Strong, R., & Troxel, D. E. (1970) · IEEE Transactions on Man Machine Systems · doi:10.1109/tmms.1970.299965 · Cited by 145 · see citing works
Treatment of chronic pain by stimulation of fibers of primary afferent neuron.
Wh, S., & Jg, W. (1968) · PubMed · Cited by 132 · see citing works
The effect of peripheral nerve block on the appreciation and execution of finger movements
Provins, K. A. (1958) · The Journal of Physiology · doi:10.1113/jphysiol.1958.sp006043 · Cited by 111 · see citing works
Kinesthetic Sensing for the EMG Controlled "Boston Arm"
Mann, R. W., & Reimers, S. (1970) · IEEE Transactions on Man Machine Systems · doi:10.1109/tmms.1970.299971 · Cited by 108 · see citing works
Hand Prosthesis Control Via Myoelectric Patterns
Herberts, P., Almström, C., Kadefors, R., & Lawrence, P. D. (1973) · Acta Orthopaedica Scandinavica · doi:10.3109/17453677308989075 · Cited by 97 · see citing works
(1974) · PubMed · Cited by 89 · see citing works
A Percutaneous Wire Electrode for Chronic Research Use
Caldwell, C. W., & RESWICK, J. B. (1975) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1975.324516 · Cited by 79 · see citing works
The Control of Upper‐Extremity Prostheses and Orthoses
MAXWELL, C. M. (1975) · The Medical Journal of Australia · doi:10.5694/j.1326-5377.1975.tb95195.x · Cited by 77 · see citing works
Pfeiffer, E. A. (1968) · Medical & Biological Engineering & Computing · doi:10.1007/bf02474726 · Cited by 67 · see citing works
NEURAL ORGANIZATION AND ITS RELEVANCE TO PROSTHETICS
Simpson, D. C. (1974) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.37.12.1393 · Cited by 63 · see citing works
Transmission of Pictorial Information Through the Skin
Collins, C. C., & Bach‐y‐Rita, P. (1973) · Advances in biological and medical physics · doi:10.1016/b978-0-12-005214-1.50010-8 · Cited by 60 · see citing works
Artificial touch in a hand-prosthesis
Beeker, T. W., During, J., & den Hertog, A. (1967) · Medical & Biological Engineering & Computing · doi:10.1007/bf02478841 · Cited by 55 · see citing works
High speed replication of submicron features on large areas by X-ray lithography
Maydan, D., Coquin, G. A., Maldonado, J. R., Somekh, S., Lou, D., & Taylor, G. N. (1975) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1975.18156 · Cited by 49 · see citing works
Sensory feedback for powered limb prostheses
Rohland, T. A. (1975) · Medical & Biological Engineering & Computing · doi:10.1007/bf02477743 · Cited by 34 · see citing works
The Control of upper-extremity prostheses and orthoses
Herberts, P. (1974) · Thomas eBooks · Cited by 32 · see citing works
Dynamics of Human Operator Control Systems Using Tactile Feedback
WEISSENBERGER, S., & Sheridan, T. B. (1962) · Journal of Basic Engineering · doi:10.1115/1.3657305 · Cited by 12 · see citing works
A comparison of materials for percutaneous connectors
Kadefors, R., Herberts, P., & Almström, C. (1974) · Annals of Biomedical Engineering · doi:10.1007/bf02368498 · Cited by 4 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Electrotactile and vibrotactile displays for sensory substitution systems
Kaczmarek, K. A., Webster, J. G., Bach-y-Rita, P., & Tompkins, W. J. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68204 · Cited by 827 · see citing works
Robotic touch shifts perception of embodiment to a prosthesis in targeted reinnervation amputees
Marasco, P. D., Kim, K., Colgate, J. E., Peshkin, M. A., & Kuiken, T. A. (2011) · Brain · doi:10.1093/brain/awq361 · Cited by 335 · see citing works
The neural basis of perceived intensity in natural and artificial touch
Graczyk, E. L., Schiefer, M. A., Saal, H. P., Delhaye, B. P., Bensmaia, S. J., & Tyler, D. J. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf5187 · Cited by 258 · see citing works
Schiefer, M., Tan, D., Sidek, S. M., & Tyler, D. J. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/1/016001 · Cited by 255 · see citing works
Electrocutaneous Stimulation for Sensory Communication in Rehabilitation Engineering
Szeto, A. Y. J., & Saunders, F. A. (1982) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1982.324948 · Cited by 224 · see citing works
D’Anna, E., Petrini, F. M., Artoni, F., Popovic, I., Igor, S., Raspopović, S., & Micera, S. (2017) · Scientific Reports · doi:10.1038/s41598-017-11306-w · Cited by 215 · see citing works
Safety of long-term electrical peripheral nerve stimulation: review of the state of the art
Günter, C., Delbeke, J., & Ortiz-Catalan, M. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0474-8 · Cited by 198 · see citing works
Horch, K., Meek, S., Taylor, T. G., & Hutchinson, D. T. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2162635 · Cited by 194 · see citing works
Wheeler, J. W., Bark, K., Savall, J., & Cutkosky, M. R. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039602 · Cited by 146 · see citing works
Peckham, P. H., Mortimer, J. T., & Marsolais, E. B. (1980) · Annals of Biomedical Engineering · doi:10.1007/bf02363440 · Cited by 145 · see citing works
Chai, G., Sui, X., Li, S., He, L., & Lan, N. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/6/066002 · Cited by 131 · see citing works
Real-time simultaneous and proportional myoelectric control using intramuscular EMG
Smith, L. H., Kuiken, T., & Hargrove, L. J. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/6/066013 · Cited by 128 · see citing works
Valle, G., Petrini, F. M., Strauss, I., Iberite, F., D’Anna, E., Granata, G., Controzzi, M., Cipriani, C., Stieglitz, T., Rossini, P. M., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-34910-w · Cited by 117 · see citing works
Integrated and flexible multichannel interface for electrotactile stimulation
Strbac, M. D., Belić, M., Isaković, M. S., Kojić, V., Bijelić, G., Popović, I., Radotić, M., Dosen, S. S., Marković, M., Farina, D., et al. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/4/046014 · Cited by 106 · see citing works
Paradigms for restoration of somatosensory feedback via stimulation of the peripheral nervous system
Pasluosta, C. F., Kiele, P., & Stieglitz, T. (2017) · Clinical Neurophysiology · doi:10.1016/j.clinph.2017.12.027 · Cited by 97 · see citing works
Sensory-feedback system compatible with myoelectric control
Scott, R. N., Brittain, R. H., Caldwell, R. R., Cameron, A. B., & Dunfield, V. A. (1980) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442481 · Cited by 93 · see citing works
Cutaneous/Tactile Haptic Feedback in Robotic Teleoperation: Motivation, Survey, and Perspectives
Pacchierotti, C., & Prattichizzo, D. (2023) · IEEE Transactions on Robotics · doi:10.1109/tro.2023.3344027 · Cited by 87 · see citing works
Neural feedback strategies to improve grasping coordination in neuromusculoskeletal prostheses
Mastinu, E., Engels, L. F., Clemente, F., Dione, M., Sassu, P., Aszmann, O. C., Brånemark, R., Håkansson, B. E. V., Controzzi, M., Wessberg, J., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-67985-5 · Cited by 82 · see citing works
Frequency Shapes the Quality of Tactile Percepts Evoked through Electrical Stimulation of the Nerves
Graczyk, E. L., Christie, B. P., He, Q., Tyler, D. J., & Bensmaia, S. J. (2022) · Journal of Neuroscience · doi:10.1523/jneurosci.1494-21.2021 · Cited by 77 · see citing works
D’Alonzo, M., Dosen, S. S., Cipriani, C., & Farina, D. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2266482 · Cited by 76 · see citing works
Transcutaneous Electrical Nerve Stimulation for Phantom Pain and Stump Pain in Adult Amputees
Mulvey, M. R., Radford, H. E., Fawkner, H. J., Hirst, L., Neumann, V., & Johnson, M. I. (2012) · Pain Practice · doi:10.1111/j.1533-2500.2012.00593.x · Cited by 75 · see citing works
Intrafascicular stimulation of monkey arm nerves evokes coordinated grasp and sensory responses
Ledbetter, N. M., Ethier, C., Oby, E. R., Hiatt, S. D., Wilder, A. M., Ko, J. H., Agnew, S. P., Miller, L. E., & Clark, G. A. (2013) · Journal of Neurophysiology · doi:10.1152/jn.00688.2011 · Cited by 69 · see citing works
Evaluation of sensation evoked by electrocutaneous stimulation on forearm in nondisabled subjects
Geng, B., Yoshida, K., Petrini, L., & Jensen, W. (2012) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.09.0187 · Cited by 59 · see citing works
The impact of the stimulation frequency on closed-loop control with electrotactile feedback
Paredes, L. P., Dosen, S. S., Rattay, F., Graimann, B., & Farina, D. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0022-8 · Cited by 46 · see citing works
Electrocutaneous Pulse Rate and Pulse Width Psychometric Functions for Sensory Communications
Szeto, A. Y. J., Lyman, J., & Prior, R. E. (1979) · Human Factors The Journal of the Human Factors and Ergonomics Society · doi:10.1177/001872087902100212 · Cited by 46 · see citing works
Lozano, C., Kaczmarek, K. A., & Santello, M. (2009) · Somatosensory & Motor Research · doi:10.1080/08990220903158797 · Cited by 45 · see citing works
Clinical application study of multifunctional prosthetic hands
Herberts, P., Almström, C., & Caine, K. (1978) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.60b4.711808 · Cited by 43 · see citing works
Control of upper-limb prostheses
Luca, C. J. D. (1978) · Journal of Medical Engineering & Technology · doi:10.3109/03091907809161756 · Cited by 41 · see citing works
Garenfeld, M. A., Mortensen, C. K., Strbac, M. D., Dideriksen, J. L., & Dosen, S. S. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/aba4fd · Cited by 39 · see citing works
Zhang, J., Hao, M., Yang, F., Liang, W., Sun, A., Chou, C.-H., & Lan, N. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac6062 · Cited by 34 · see citing works
A compact system for simultaneous stimulation and recording for closed-loop myoelectric control
Garenfeld, M. A., Jorgovanović, N., Ilić, V., Strbac, M. D., Isaković, M. S., Dideriksen, J. L., & Dosen, S. S. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00877-5 · Cited by 32 · see citing works
Fisher, L. E., Ayers, C. A., Ciollaro, M., Ventura, V., Weber, D. J., & Gaunt, R. A. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/3/036007 · Cited by 29 · see citing works
Ayers, C. A., Fisher, L. E., Gaunt, R. A., & Weber, D. J. (2016) · Journal of Neurophysiology · doi:10.1152/jn.00961.2015 · Cited by 28 · see citing works
Closed-loop Control using Electrotactile Feedback Encoded in Frequency and Pulse Width
Dideriksen, J. L., Mercader, I. U., & Dosen, S. S. (2020) · IEEE Transactions on Haptics · doi:10.1109/toh.2020.2985962 · Cited by 27 · see citing works
Gonzalez-Vargas, J. E., Dosen, S. S., Amsuess, S., Yu, W., & Farina, D. (2015) · PLoS ONE · doi:10.1371/journal.pone.0127528 · Cited by 26 · see citing works
Electrotactile Stimulator for Artificial Proprioception
Nohama, P., Lopes, A. V., & Cliquet, A. (1995) · Artificial Organs · doi:10.1111/j.1525-1594.1995.tb02318.x · Cited by 24 · see citing works
Ideas on sensory feedback in hand prostheses
Herberts, P., & Körner, L. K. (1979) · Prosthetics and Orthotics International · doi:10.3109/03093647909103104 · Cited by 22 · see citing works
Self-citationD’Alonzo, M., Engels, L. F., Controzzi, M., & Cipriani, C. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa81e2 · Cited by 21 · see citing works
Wang, T., Li, S., Chai, G., & Lan, N. (2013) · IEEE International Conference on Information Science and Technology (ICIST) · doi:10.1109/icist.2013.6747492 · Cited by 19 · see citing works
Clinical Applications and Future Translation of Somatosensory Neuroprostheses
Graczyk, E. L., Hutchison, B. C., Valle, G., Bjånes, D. A., Gates, D. H., Raspopović, S., & Gaunt, R. A. (2024) · Journal of Neuroscience · doi:10.1523/jneurosci.1237-24.2024 · Cited by 17 · see citing works
Anani, A., & Körner, L. K. (1979) · Medical & Biological Engineering & Computing · doi:10.1007/bf02447053 · Cited by 14 · see citing works
Self-citationICITST-2013: Keynote speaker 2: Security challenge of TOR and the deep web
Stupples, D. W. (2013) · International Conference for Internet Technology and Secured Transactions · doi:10.1109/icitst.2013.6750149 · Cited by 13 · see citing works
Optimization of single electrode tactile codes
Szeto, A. Y. J., & Farrenkopf, G. R. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368611 · Cited by 10 · see citing works
Almström, C., Anani, A., Herberts, P., & Körner, L. K. (1981) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442780 · Cited by 10 · see citing works
Self-citationKörner, L. (1979) · Acta Orthopaedica Scandinavica · doi:10.3109/ort.1979.50.suppl-178.01 · Cited by 10 · see citing works
Self-citationDosen, S. S., Prahm, C., Amsuess, S., Vujaklija, I., & Farina, D. (2021) · Springer eBooks · doi:10.1007/978-3-030-60746-3_15 · Cited by 9 · see citing works
Hokanson, J., Ayers, C. A., Gaunt, R. A., Bruns, T. M., & Weber, D. J. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091857 · Cited by 8 · see citing works
Kolarcik, C. L., Castro, C. A., Lesniak, A. J., Demetris, A. J., Fisher, L. E., Gaunt, R. A., Weber, D. J., & Cui, X. T. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab94d7 · Cited by 7 · see citing works
Basic study of vibrotactile sensory feedback system for biomimetic powered-prosthetic hand
Okuno, R., Yoshida, M., Uchiyama, T., & Akazawa, K. (1996) · IEEJ Transactions on Electronics Information and Systems · doi:10.1541/ieejeiss1987.116.11_1246 · Cited by 6 · see citing works
Earley, E. J., & Ortiz-Catalan, M. (2023) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner52421.2023.10123893 · Cited by 5 · see citing works
Discrimination of Spatial and Temporal Parameters in Electrocutaneous Stimulation
Geng, B., & Paramanathan, S. A. (2016) · International Journal of Physical Medicine & Rehabilitation · doi:10.4172/2329-9096.1000333 · Cited by 5 · see citing works
Combined spatial and frequency encoding for electrotactile feedback of myoelectric signals
Nataletti, S., Leo, F., Dideriksen, J. L., Brayda, L. G., & Dosen, S. S. (2022) · Experimental Brain Research · doi:10.1007/s00221-022-06409-4 · Cited by 5 · see citing works
Solomonow, M., Herskovitz, J. S., & Lyman, J. (1979) · Annals of Biomedical Engineering · doi:10.1007/bf02363131 · Cited by 5 · see citing works
Prosthetics and orthotics in Latin America/1
Jensen, E. (1979) · Prosthetics and Orthotics International · doi:10.3109/03093647909103103 · Cited by 4 · see citing works
Ifukube, T. (1989) · Journal of the Robotics Society of Japan · doi:10.7210/jrsj.7.496 · Cited by 4 · see citing works
Neuroprostheses for somatosensory function
Fisher, L. E., Hokanson, J., & Weber, D. J. (2015) · Elsevier eBooks · doi:10.1016/b978-1-78242-101-6.00006-9 · Cited by 3 · see citing works
Decoding force from multiunit recordings from the median nerve
Wright, J. C., Macefield, V. G., André, V. S., & Tapson, J. C. (2015) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2015.7281327 · Cited by 3 · see citing works
Automatic hand phantom map generation and detection using decomposition support vector machines
Huang, H., Bruschini, C. E., Antfolk, C., Enz, C., Li, T., Justiz, J., & Koch, V. M. (2018) · BioMedical Engineering OnLine · doi:10.1186/s12938-018-0502-8 · Cited by 3 · see citing works
How Fast Is Too Fast? Boundaries to the Perception of Electrical Stimulation of Peripheral Nerves
Dupan, S. S. G., McNeill, Z., Sarda, E., Brunton, E., & Nazarpour, K. (2022) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2022.3158067 · Cited by 2 · see citing works
Somatosensory Neuromodulation with a Focus Towards Clinical Systems
Graczyk, E. L., & Tyler, D. J. (2022) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_92-1 · Cited by 2 · see citing works
Gozzi, N., & Valle, G. (2023) · Elsevier eBooks · doi:10.1016/b978-0-443-18498-7.00014-4 · Cited by 2 · see citing works
The High-Tech Hand Surgery Interface
Rose, E. H. (1986) · Clinics in Plastic Surgery · doi:10.1016/s0094-1298(20)31600-x · Cited by 2 · see citing works
On sensory feedback in hand prostheses
Antfolk, C. (2012) · Lund University Publications (Lund University) · Cited by 2 · see citing works
Point contact and relative motion of drawing can identify individual traits
Yabuki, K., Tsujita, K., Goan, M., Kihara, S., & Okazaki, K. (2014) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc.2014.6974083 · Cited by 1 · see citing works
Gender effect on discrimination of location and frequency in surface electrical stimulation
Geng, B., Paramanathan, S. A., Pedersen, K. F., Lauridsen, M. V., Gade, J., Lontis, R., & Jensen, W. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318795 · Cited by 1 · see citing works
Somatosensory Neuromodulation with a Focus Towards Clinical Systems
Graczyk, E. L., & Tyler, D. J. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_92 · Cited by 1 · see citing works
Voluntary Control of Muscle Activity
Yates, A. J. (1980) · Springer eBooks · doi:10.1007/978-1-4684-3554-2_3
Toward a Mobility Aid for the Blind
Browne, R. F. (2003)
Hokanson, J. (2014) · D-Scholarship@Pitt (University of Pittsburgh)
Goan, M., Tsujita, K., Kihara, S., & Okazaki, K. (2015) · Mathematics for industry · doi:10.1007/978-4-431-55429-5_7
Peripheral Nerve Interface Applications, Sensory Restoration
Fisher, L. E., & Weber, D. J. (2022) · Springer eBooks · doi:10.1007/978-1-0716-1006-0_206
Peripheral Nerve Interface Applications, Sensory Restoration
Fisher, L. E., & Weber, D. J. (2015) · Springer eBooks · doi:10.1007/978-1-4614-6675-8_206
Peripheral Nerve Interface Applications, Sensory Restoration
Fisher, L. E., & Weber, D. J. (2014) · Springer eBooks · doi:10.1007/978-1-4614-7320-6_206-1
- Authors
- Anani, A. B., Ikeda, K., & Körner, L. M.
- Affiliations
- Sahlgrenska University Hospital (SE)
- Venue
- Medical & Biological Engineering & Computing
- Published
- 1977-07
- Volume
- 15
- Issue
- 4
- Pages
- 363-373
- ISSN
- 0140-0118 (ISSN-L)
- 1741-0444
- OpenAlex
- W1968532283
- Cited by
- 74
- References
- 19
- Citations by year
- 2024: 1 · 2023: 4 · 2022: 6 · 2021: 2 · 2020: 5 · 2019: 1 · 2018: 2 · 2017: 3 · 2016: 4 · 2015: 9 · 2014: 5 · 2013: 3 · 2012: 4
- FWCI
- 1.38
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Medical & Biological Engineering & Computing (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Keywords
- sensory feedback, powered prostheses, paresthesia, information transfer rate, electrode placement
- MeSH terms
- Adult, Discrimination, Psychological, Electric Stimulation, Feedback, Female, Humans, Male, Neurons, Afferent, Prosthesis Design
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›