The DOI matches its Crossref record.
A carbon nanotube/polymer strain sensor with linear and anti-symmetric piezoresistivity
Abstract
In this article, a strain sensor made from an epoxy-based nanocomposite using a kind of multi-walled carbon nanotubes (MWNTs), i.e., LMWNT-10, was investigated. It was found that the piezoresistivity of this strain sensor is linear and anti-symmetric in tensile and compressive states within a large strain range, which is different from that of the strain sensor using another type of MWNTs, i.e., MWNT-7, in our previous reports. This linear and anti-symmetric piezoresistivity is very suitable for practical sensor applications. In our experiments, both static and dynamic responses of the two sensors were measured. The experimental results indicate that the completely different piezoresistivity characteristics of the two sensors are probably due to the complete different working mechanisms. For the sensor made from LMWNT-10, the present experimental investigations reveal that its working mechanism should be the piezoresistivity of MWNTs due to deformation of MWNTs. On the other hand, for the strain sensor made from MWNT-7, the dominant working mechanism of this sensor is the tunneling effect caused by the distance changes among carbon nanotubes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sensitive electromechanical sensors using viscoelastic graphene-polymer nanocomposites
Boland, C. S., Khan, U., Ryan, G., Barwich, S., Charifou, R., Harvey, A., Backes, C., Li, Z., Ferreira, M. S., Möbius, M. E., et al. (2016) · Science · doi:10.1126/science.aag2879 · Cited by 823
Sensitive, High-Strain, High-Rate Bodily Motion Sensors Based on Graphene–Rubber Composites
Boland, C. S., Khan, U., Backes, C., O’Neill, A., McCauley, J., Duane, S., Shanker, R., Liu, Y., Jurewicz, I., Dalton, A. B., et al. (2014) · ACS Nano · doi:10.1021/nn503454h · Cited by 793
Self-citationPiezoresistive Strain Sensors Made from Carbon Nanotubes Based Polymer Nanocomposites
Alamusi, Hu, N., Fukunaga, H., Atobe, S., Liu, Y., & Li, J. (2011) · Sensors · doi:10.3390/s111110691 · Cited by 633
Self-citationStretchable and highly sensitive graphene-on-polymer strain sensors
Li, X., Zhang, R., Yu, W., Wang, K., Wei, J., Wu, D., Cao, A., Li, Z., Cheng, Y., Zheng, Q., et al. (2012) · Scientific Reports · doi:10.1038/srep00870 · Cited by 610
A Review: Carbon Nanotube-Based Piezoresistive Strain Sensors
Obitayo, W., & Liu, T. (2012) · Journal of Sensors · doi:10.1155/2012/652438 · Cited by 336
Metadata
- Authors
- Yin, G., Hu, N., Karube, Y., Liu, Y., Li, Y., & Fukunaga, H.
- Venue
- Journal of Composite Materials
- Publisher
- SAGE Publications
- Published
- 2011-04-26
- Volume
- 45
- Issue
- 12
- Pages
- 1315-1323
- ISSN
- 0021-9983 (ISSN-L)
- 1530-793X
- OpenAlex
- W1993764392
- Cited by
- 206
- References
- 0
- FWCI
- 7.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A carbon nanotube/polymer strain sensor with linear and anti-symmetric piezoresistivity. https://app.cochat.ai/papers/10.1177/0021998310393296
- The paper
- Yin, G., Hu, N., Karube, Y., Liu, Y., Li, Y., & Fukunaga, H. (2011). A carbon nanotube/polymer strain sensor with linear and anti-symmetric piezoresistivity. Journal of Composite Materials. https://doi.org/10.1177/0021998310393296
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.