The Competition between the Composite-Dentin Bond Strength and the Polymerization Contraction Stress
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The influence of contraction stresses, developed during the polymerization of composites, on adhesion to dentin treated with a dentin adhesive was studied for a chemically- and a light-activated microfilled composite, in both linear and 3-D models. The linear model consisted of an arrangement set up in a tensilometer in which the composites could be applied to a flat dentin surface fixed to the stationary cross-head at one end, and mechanically clamped to the cross-head connected to the load cell at the other end. The increase of the bond strength was measured at different time intervals from the start of mixing and was compared with the developing contraction stress. Throughout the complete polymerization process, the adhesion survived the contraction stress, which is explained by flow relaxation, which can occur sufficiently in this configuration. In the three-dimensional model, the composites are attached to more than two dentin walls. In this situation, flow is severely limited, and contraction stress values can exceed the bond strength, leading to separation. This was demonstrated in Class V cavities. The shape of the cavity is considered to be of great importance in conservation of the composite-dentin bond.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bovine Teeth as Possible Substitutes in the Adhesion Test
Nakamichi, I., Iwaku, M., & Fusayama, T. (1983) · Journal of Dental Research · doi:10.1177/00220345830620101501 · Cited by 623
Relaxation of Polymerization Contraction Stresses by Flow in Dental Composites
Davidson, C. L., & De Gee, A. J. (1984) · Journal of Dental Research · doi:10.1177/00220345840630021001 · Cited by 478
Self-citation
Cited by
Setting Stress in Composite Resin in Relation to Configuration of the Restoration
Feilzer, A. J., De Gee, A. J., & Davidson, C. L. (1987) · Journal of Dental Research · doi:10.1177/00220345870660110601 · Cited by 1,168
Self-citationPolymerization shrinkage and polymerization shrinkage stress in polymer-based restoratives
Davidson, C. L., & Feilzer, A. J. (1997) · Journal of Dentistry · doi:10.1016/s0300-5712(96)00063-2 · Cited by 729
Self-citationPolymerization shrinkage and elasticity of flowable composites and filled adhesives
Labella, R., Lambrechts, P., Van Meerbeek, B., & Vanherle, G. (1999) · Dental Materials · doi:10.1016/s0109-5641(99)00022-6 · Cited by 597
Microtensile bond strength between adhesive cements and root canal dentin
Bouillaguet, S., Troesch, S., Wataha, J. C., Krejci, I., Meyer, J.-M., & Pashley, D. H. (2003) · Dental Materials · doi:10.1016/s0109-5641(02)00030-1 · Cited by 531
Complete Marginal Seal of Class V Resin Composite Restorations Effected by Increased Flexibility
Kemp-Scholte, C. M., & Davidson, C. L. (1990) · Journal of Dental Research · doi:10.1177/00220345900690060301 · Cited by 363
Self-citation
Metadata
- Authors
- Davidson, C. L., De Gee, A. J., & Feilzer, A.
- Venue
- Journal of Dental Research
- Publisher
- SAGE Publications
- Published
- 1984-12
- Volume
- 63
- Issue
- 12
- Pages
- 1396-1399
- ISSN
- 0022-0345 (ISSN-L)
- 1544-0591
- OpenAlex
- W2023450796
- Cited by
- 815
- References
- 2
- FWCI
- 26.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.