The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Adhesion to Dentin and Physical Properties of a Light-cured Glass-ionomer Liner/Base
Abstract
The objective of this study was to determine the adhesion to dentin and the physical properties of Vitrabond Light Cure Glass Ionomer Liner/Base and to compare these values with those of a conventional material, 3M Glass Ionomer Liner (3MGI). Shear bond strengths to bovine dentin after 24 h in distilled water were determined to be 12 ± 3 MPa for Vitrabond Liner/Base, while for 3MGI, bond strengths were 4 ± 2 MPa. The failure mode was cohesive in dentin or the ionomer. Immediate adhesion of the light-cured material was also significantly higher than that of the conventional glass-ionomer liner. Thermal cycling experiments showed that the bond of Vitrabond Liner/Base to dentin was a stable one. Adhesion studies carried out on human dentin showed high adhesion values as well. Compressive and diametral tensile strengths for Vitrabond Liner/Base were determined immediately after light curing and also after storage in water for 24 h, one week, one month, and seven months. There was no significant difference in the values of compressive and diametral tensile strengths obtained immediately after curing and after extended storage in water at 37°C.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new translucent cement for dentistry. The glass ionomer cement
Wilson, A. D., & Kent, B. E. (1972) · British Dental Journal · doi:10.1038/sj.bdj.4802810 · Cited by 892
Mechanism of Adhesion of Polyelectrolyte Cements to Hydroxyapatite
Wilson, A. D., Prosser, H. J., & Powis, D. M. (1983) · Journal of Dental Research · doi:10.1177/00220345830620051801 · Cited by 245
Physical properties of calcium hydroxide and glass-ionomer base and lining materials
Tam, L. E., Pulver, E., McComb, D., et al. (1989) · Dental Materials · doi:10.1016/0109-5641(89)90001-8 · Cited by 53
Cited by
Modifications in Glass Ionomer Cements: Nano-Sized Fillers and Bioactive Nanoceramics
Najeeb, S., Khurshid, Z., Zafar, M., Khan, A., Zohaib, S., Martí, J., Sauro, S., Matinlinna, J., & Rehman, I. (2016) · International Journal of Molecular Sciences · doi:10.3390/ijms17071134 · Cited by 226
“RMGICs micromechanically bond to dentine through infiltration of the collagen network previously exposed by using a 10% polyacrylic acid pre-treatment, in combination with chemical bonding obtained by ionic interaction of carboxyl groups from the acid with calcium ions of remaining HAP crystals within the partially de…”
MethodSimonsen, R. J. (1991) · The Journal of the American Dental Association · doi:10.14219/jada.archive.1991.0217 · Cited by 31
Metadata
- Authors
- Mitra, S. B.
- Venue
- Journal of Dental Research
- Publisher
- SAGE Publications
- Published
- 1991-01
- Volume
- 70
- Issue
- 1
- Pages
- 72-74
- ISSN
- 0022-0345 (ISSN-L)
- 1544-0591
- OpenAlex
- W2006469698
- Cited by
- 329
- References
- 3
- FWCI
- 28.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Adhesion to Dentin and Physical Properties of a Light-cured Glass-ionomer Liner/Base. https://app.cochat.ai/papers/10.1177/00220345910700011201
- The paper
- Mitra, S. B. (1991). Adhesion to Dentin and Physical Properties of a Light-cured Glass-ionomer Liner/Base. Journal of Dental Research. https://doi.org/10.1177/00220345910700011201
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.