Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 456

The DOI matches its Crossref record.

Wear and Marginal Breakdown of Composites with Various Degrees of Cure

Ferracane, J.L., Mitchem, J.C., Condon, J.R., Todd, R.·1997·Journal of Dental Research

Abstract

Loss of anatomical form due to wear has been cited as one factor limiting the clinical use of posterior composites. The physical properties and possibly the wear resistance of composite are influenced by the extent to which it is cured. The aim of this study was to vary degree of conversion (DC) in composites to test the hypothesis that resistance to wear and marginal breakdown could be improved by enhanced curing. A light-cured hybrid composite containing a 50% Bis-GMA/50% TEGDMA resin and 62 vol% of strontium glass (1 to 2 μm) with microfill silica was formulated (Bisco). Composite was placed into two 2.5-mm-diameter cylindrical holes in Co-Cr teeth replacing first and second molars in the mandibular dentures of 50 edentulous patients. The composites were light-cured for different time periods (9 s, 12 s, 25 s, 40 s, and 40 s + 10 min at 120°C) and then polished. The microfill Heliomolar was also tested. DC (%) was measured by FTIR and ranged between 55% for 9 s of light-curing and 67% for 40 s of light-curing followed by heat application. Impressions were evaluated at baseline, 6 mo, 1 yr, and 2 yrs. Stone casts were evaluated independently by three observers to determine the % of the total margin exhibiting breakdown. Epoxy replicas were measured with a profilometer for wear. Wear of the hybrid composite at 2 yrs ranged from a high of 144 μm with 9 s of light-curing to a low of 36 μm with 40 s of light-curing followed by heat. Heliomolar exhibited from 11 to 16 μm of wear at 2 yrs. There was a strong negative correlation (r 2 = 0.91) between the degree of cure and the abrasive wear of the hybrid composites. Marginal breakdown was negligible for the hybrids, and was reduced for the microfill from 40% to 15% of the margin by heat treatment. This study showed that the resistance to abrasive wear of a dental composite could be improved by enhancement of its degree of conversion.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/00220345970760081401

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 456

Metadata

Authors
Ferracane, J. L., Mitchem, J. C., Condon, J. R., & Todd, R.
Venue
Journal of Dental Research
Published
1997-08
Volume
76
Issue
8
Pages
1508-1516
ISSN
  • 0022-0345 (ISSN-L)
  • 1544-0591
OpenAlex
W1976859118
Cited by
456
References
0
FWCI
19.12
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Wear and Marginal Breakdown of Composites with Various Degrees of Cure. https://app.cochat.ai/papers/10.1177/00220345970760081401
The paper
Ferracane, J. L., Mitchem, J. C., Condon, J. R., & Todd, R. (1997). Wear and Marginal Breakdown of Composites with Various Degrees of Cure. Journal of Dental Research. https://doi.org/10.1177/00220345970760081401

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.