Amplification Methods to Increase the Sensitivity of In Situ Hybridization: Play CARD(S)
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In situ hybridization (ISH) has proved to be an invaluable molecular tool in research and diagnosis to visualize nucleic acids in their cellular environment. However, its applicability can be limited by its restricted detection sensitivity. During the past 10 years, several strategies have been developed to improve the threshold levels of nucleic acid detection in situ by amplification of either target nucleic acid sequences before ISH (e.g., in situ PCR) or the detection signals after the hybridization procedures. Here we outline the principles of tyramide signal amplification using the catalyzed reporter deposition (CARD) technique, present practical suggestions to efficiently enhance the sensitivity of ISH with CARD, and discuss some applications and possible future directions of in situ nucleic acid detection using such an amplification strategy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Visualization of Single RNA Transcripts in Situ
Femino, A. M., Fay, F. S., Fogarty, K., & Singer, R. H. (1998) · Science · doi:10.1126/science.280.5363.585 · Cited by 1,504 · cited 1×
“The ultimate mRNA detection limit is more difficult to determine but may reach the level of single mRNA molecules in the most optimal test systems (Femino et al. 1998).”
Background
Cited by
Pernthaler, A., Pernthaler, J., & Amann, R. (2002) · Applied and Environmental Microbiology · doi:10.1128/aem.68.6.3094-3101.2002 · Cited by 1,065
Technical Aspects of Immunohistochemistry
Ramos-Vara, J. A. (2005) · Veterinary Pathology · doi:10.1354/vp.42-4-405 · Cited by 905
Programmable in situ amplification for multiplexed imaging of mRNA expression
Choi, H. M. T., Chang, J. Y., Trinh, L. A., Padilla, J. E., Fraser, S. E., & Pierce, N. A. (2010) · Nature Biotechnology · doi:10.1038/nbt.1692 · Cited by 715
Next-Generation in Situ Hybridization Chain Reaction: Higher Gain, Lower Cost, Greater Durability
Choi, H. M. T., Beck, V. A., & Pierce, N. A. (2014) · ACS Nano · doi:10.1021/nn405717p · Cited by 629
Highly multiplexed in situ protein imaging with signal amplification by Immuno-SABER
Saka, S. K., Wang, Y., Kishi, J. Y., Zhu, A., Zeng, Y., Xie, W., Kirli, K., Yapp, C., Cicconet, M., Beliveau, B. J., et al. (2018) · doi:10.1101/507566 · Cited by 485
“For such high levels of amplification, catalyzed reporter deposition-based TSA is considered a gold-standard, which was reported to achieve 10-1000-fold sensitivity improvement under different assay types and comparison conditions 24, 50-53 .”
Metadata
- Authors
- Speel, E. J. M., Hopman, A. H. N., & Komminoth, P.
- Venue
- Journal of Histochemistry & Cytochemistry
- Publisher
- SAGE Publications
- Published
- 1999-03
- Volume
- 47
- Issue
- 3
- Pages
- 281-288
- ISSN
- 0022-1554 (ISSN-L)
- 1551-5044
- OpenAlex
- W2141686439
- Cited by
- 181
- References
- 1
- FWCI
- 4.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.