State of the art in vivo imaging techniques for laboratory animals
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
In recent decades, imaging devices have become indispensable tools in the basic sciences, in preclinical research and in modern drug development. The rapidly evolving high-resolution in vivo imaging technologies provide a unique opportunity for studying biological processes of living organisms in real time on a molecular level. State of the art small-animal imaging modalities provide non-invasive images rich in quantitative anatomical and functional information, which renders longitudinal studies possible allowing precise monitoring of disease progression and response to therapy in models of different diseases. The number of animals in a scientific investigation can be substantially reduced using imaging techniques, which is in full compliance with the ethical endeavours for the 3R (reduction, refinement, replacement) policies formulated by Russell and Burch; furthermore, biological variability can be alleviated, as each animal serves as its own control. The most suitable and commonly used imaging modalities for in vivo small-animal imaging are optical imaging (OI), ultrasonography (US), computed tomography (CT), magnetic resonance imaging (MRI), and finally the methods of nuclear medicine: positron emission tomography (PET) and single photon emission computed tomography (SPECT).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photoacoustic tomography: In vivo imaging from organelles to organs
Wang, L. V., & Hu, S. (2012) · Science · doi:10.1126/science.1216210 · Cited by 4,331 · cited 1×
“A fraction of incident light pulse energy is absorbed by the target tissue causing thermal expansion, which propagates as a sound wave and can thus be detected by an acoustic detector, providing both structural and compositional information with depth penetration from over several millimetres to centimetres.(102,103)…”
BackgroundWeissleder, R., & Mahmood, U. (2001) · Radiology · doi:10.1148/radiology.219.2.r01ma19316 · Cited by 1,315
Magnetic Resonance Spectroscopy
Gujar, S. K., Maheshwari, S., Bj??rkman-Burtscher, I., & Sundgren, P. C. (2005) · Journal of Neuro-Ophthalmology · doi:10.1097/01.wno.0000177307.21081.81 · Cited by 380
Cited by
Deep learning-enabled multi-organ segmentation in whole-body mouse scans
Schoppe, O., Pan, C., Coronel, J., Mai, H., Rong, Z., Todorov, M. I., Müskes, A., Navarro, F., Li, H., Ertürk, A., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-19449-7 · Cited by 104
Welniak–Kaminska, M., Fiedorowicz, M., Orzel, J., Bogorodzki, P., Modlinska, K., Stryjek, R., Chrzanowska, A., Pisula, W., & Grieb, P. (2019) · PLOS ONE · doi:10.1371/journal.pone.0215348 · Cited by 61
Beyond luciferase-luciferin system: modification, improved imaging and biomedical application
Jiang, Y., Shi, X., Tang, C., & Wang, F. (2023) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2023.215045 · Cited by 22
Metadata
- Authors
- Lauber, D. T., Fülöp, A., Kovács, T., Szigeti, K., Máthé, D., & Szijártó, A.
- Venue
- Laboratory Animals
- Publisher
- SAGE Publications
- Published
- 2017-02-26
- Volume
- 51
- Issue
- 5
- Pages
- 465-478
- ISSN
- 0023-6772 (ISSN-L)
- 1758-1117
- OpenAlex
- W2594895774
- Cited by
- 75
- References
- 3
- FWCI
- 4.35
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.