The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A Short History of Blood Pressure Measurement
Open accessOverview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bulletin of the New York Academy of Medicine
(1969) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1969.03160300092054 · Cited by 1,440
La circulation du sang à l'état physiologique et dans les maladies
Marey, É.-J. (1983) · Cited by 17
Research works printed but not linked: 15
- Bett W R, 1957, NAPT Bulletin, 20, 179
- Brunton L, 1908, Therapeutics of the Circulation
- Burget G E, 1925, Annals of Medical History, 7, 109
- 1939, Ciba, 1, 94
- Gispen J G W, 1957, Janus, 54, 224
- Hill L, 1897, British Medical Journal, 904, 10.1136/bmj.2.1918.904 · doi:10.1136/bmj.2.1918.904
- Hales S, 1733, Statical Essays: Containing Hæmostaticks
- 1913, Janus, 18, 333
- Klopp E H, 1974, Surgery, Gynæcology and Obstetrics, 139, 95
- Longmore D, 1969, Machines in Medicine
- Major R H, 1930, Annals of Medical History, 2, 47
- 1944, Medical Times, 72, 315
- Segall H N, 1965, Annals of Internal Medicine, 63, 147, 10.7326/0003-4819-63-1-147 · doi:10.7326/0003-4819-63-1-147
- Segall H N, 1975, Annals of Internal Medicine, 83, 561, 10.7326/0003-4819-83-4-561 · doi:10.7326/0003-4819-83-4-561
- Singer C, 1962, A Short History of Medicine
Cited by
Zhou, B., Perel, P., Mensah, G. A., & Ezzati, M. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-021-00559-8 · Cited by 1,521
Blood pressure and its variability: classic and novel measurement techniques
Schutte, A. E., Kollias, A., & Stergiou, G. S. (2022) · Nature Reviews Cardiology · doi:10.1038/s41569-022-00690-0 · Cited by 335
Recent Progress of Miniature MEMS Pressure Sensors
Song, P., Ma, Z., Ma, J., Yang, L., Wei, J., Zhao, Y., Zhang, M., Yang, F., & Wang, X. (2020) · Micromachines · doi:10.3390/mi11010056 · Cited by 262
Sharman, J. E., Avolio, A. P., Baulmann, J., Benetos, A., Blacher, J., Blizzard, C. L., Boutouyrie, P., Chen, C.-H., Chowienczyk, P., Cockcroft, J. R., et al. (2017) · European Heart Journal · doi:10.1093/eurheartj/ehw632 · Cited by 231
“The original Riva-Rocci method to measure blood pressure (BP) using a cuff at the upper arm assumed the pressure obtained by this technique was a good proxy for central aortic BP.(1,2) The clinical (prognostic) importance of brachial cuff BP is undeniable for both the assessment of cardiovascular risk associated with…”
MethodInfluentialCuff-Less and Continuous Blood Pressure Monitoring: A Methodological Review
Sharma, M., Barbosa, K., Ho, V., Griggs, D., Ghirmai, T., Krishnan, S., Hsiai, T., Chiao, J.-C., & Cao, H. (2017) · Technologies · doi:10.3390/technologies5020021 · Cited by 226
Metadata
- Authors
- Booth, J.
- Venue
- Proceedings of the Royal Society of Medicine
- Publisher
- SAGE Publications
- Published
- 1977-11
- Volume
- 70
- Issue
- 11
- Pages
- 793-799
- ISSN
- 0035-9157 (ISSN-L)
- OpenAlex
- W183316133
- Cited by
- 268
- References
- 2
- Type
- conference abstract
- Language
- en
- Open access
- bronze
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Short History of Blood Pressure Measurement. https://app.cochat.ai/papers/10.1177/003591577707001112
- The paper
- Booth, J. (1977). A Short History of Blood Pressure Measurement. Proceedings of the Royal Society of Medicine. https://doi.org/10.1177/003591577707001112
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.